Cold vapour matrix-independent generation and isotope dilution inductively coupled plasma mass spectrometry for reference measurements of Hg in marine environmental samples

被引:0
作者
Agnieszka Anna Krata
Emilia Vassileva
机构
[1] International Atomic Energy Agency,Environment Laboratories
[2] University of Warsaw,Faculty of Chemistry, Biological and Chemical Research Centre
来源
Environmental Science and Pollution Research | 2019年 / 26卷
关键词
Mercury; Marine samples; Reference measurement; Cold vapour generation; Isotope dilution mass spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
The analytical procedure for reference measurements of Hg in marine environmental samples based on cold vapour generation (CVG) inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) and isotope dilution calibration strategy (ID) is described in the present study. The procedure was applied on different matrices and varying mass fractions for mercury in oyster, marine sediment and costal seawater samples. The use of CVG for sample introduction resulted in sensitivity enhancement, reduction of blank levels, minimization of matrix interferences and the elimination of memory effects. The entire measurement process was described by mathematical equations, and all factors influencing the final results were systematically investigated. The expanded uncertainty on results was estimated following the ISO/Guide to the Expression of Uncertainty in Measurement guidelines, and all major contributions were identified. Modelling of the entire measurement process and the use of primary method of measurements ID ICP-MS related obtained values for total mercury in different types of marine matrices to the international system of units SI. Obtained results for mercury mass fractions in biota and marine sediments were used as the International Atomic Energy Agency's  contribution in the certification campaigns for marine reference materials and were in excellent agreement with the assigned reference values.
引用
收藏
页码:22051 / 22060
页数:9
相关论文
共 89 条
  • [1] Berglund M(2011)Isotopic compositions of the elements (IUPAC technical report) Pure Appl Chem 83 397-410
  • [2] Wieser ME(2017)On the use of certified reference materials for assuring the quality of results for the determination of hg in environmental samples Environ Sci Pollut Res 24 7889-7897
  • [3] Bulska E(2012)Guidance for sediment and biota monitoring under common implementation strategy for the Water Framework Directive Trends Anal Chem 36 15-24
  • [4] Krata A(2001)Development of isotope dilution cold vapour inductively coupled plasma mass spectrometry and its application to the certification of mercury in NIST standard reference materials Anal Chem 73 2190-2199
  • [5] Kałabun M(2015)Application of cold vapour-atomic absorption (CVAAS) spectrophotometry and inductively coupled plasma-atomic emission spectrometry methods for cadmium, Hg and lead analyses of fish samples. Validation of the method of CVAAS Food Control 48 37-42
  • [6] Wojciechowski M(2012)Accurate quantification of mercury in river water by isotope dilution MC-ICP-SFMS and ICP-QMS detection after cold vapour generation J Anal At Spectrom 27 1983-1989
  • [7] Carere M(2013)Rapid determination of ultra-trace concentrations of Hg in plants and soils by cold vapour inductively coupled plasma-optical emission spectrometry Microchem J 111 62-66
  • [8] Dulio V(1994)Calculating standard deviations and confidence intervals with a universally applicable spreadsheet technique Analyst 119 2161-2165
  • [9] Hanke G(2016)Reference measurements for total Hg and methyl Hg content in marine biota samples using direct or species-specific isotope dilution inductively coupled plasma mass spectrometry Talanta 160 562-569
  • [10] Polesello S(2018)Reference measurements of cadmium and lead contents in candidates for new environmental certified materials by isotope dilution inductively coupled plasma mass spectrometry Microchem J 142 36-42