Rapid Simultaneous Screening and Detection of 12 Anticoagulant Rodenticides in Food by Ultra-performance Liquid Chromatography-Triple Quadrupole/Linear Ion Trap Tandem Mass Spectrometry

被引:0
作者
Xiaoli Cao
Xiaoqian Yang
Zhong Liu
Haitao Jiao
Suhua Liu
Lanzheng Liu
Qingfen Meng
机构
[1] Jinan Municipal Center for Disease Control and Prevention,Qinghai Institute of Salt Lakes
[2] Chinese Academy of Sciences,undefined
来源
Food Analytical Methods | 2017年 / 10卷
关键词
Anticoagulant rodenticides; Multi-residue analysis; Modified QuEChERS; Food; UPLC-QTrap-MS/MS;
D O I
暂无
中图分类号
学科分类号
摘要
A rapid analytical method for the simultaneous screening and detection of 12 anticoagulant rodenticides in food samples was established based on modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) sample preparation method using an ultra-performance liquid chromatography-triple quadrupole/linear ion trap tandem mass spectrometry (UPLC-QTrap-MS/MS). Food samples were extracted and purified with modified QuEChERS method. The 12 anticoagulant rodenticides (warfarin, brodifacoum, difethialone, coumachlor, coumatetralyl, bromadiolone, chlorophacinone, difenacoum, diphacinone, pindone, valone, and flocoumafen) and the internal standard (warfarin-D5) were separated within 6 min using an ACQUITY UPLC BEH-C18 column (1.7 μm, 2.1 mm × 50 mm) and gradient elution with the mobile phase consisting of 5 mM ammonium acetate formate buffer and acetonitrile. The multiple reaction monitoring-information dependent acquisition-enhanced product ion (MRM-IDA-EPI) scanning was employed for detection. The calibration curves were linear (R2 > 0.99) for all the compounds. The mean recoveries for the 12 analytes at three spiked levels (1× LOQ, 5× LOQ, and 10× LOQ) were in the range of 79.5–113.2% with RSDs of 1.8–13.2%.The limits of detection (LOD) for the 12 rodenticides ranged from 0.01 (warfarin) to 0.05 μg/kg (diphacinone). The limit of quantification (LOQ) for the 12 rodenticides was between 0.02 (warfarin) and 0.10 μg/kg (diphacinone). The developed method was more straightforward, less time and labor intensive, and more sensitive, selective, and accurate for screening multiple anticoagulant rodenticides, and it was successfully used in several poisoning cases.
引用
收藏
页码:3538 / 3547
页数:9
相关论文
共 178 条
[1]  
Berny P(1995)Anticoagulant poisoning in animals: a simple new high-performance thin-layer chromatographic (HPTLC) method for the simultaneous detection of eight anticoagulant rodenticides in liver samples J Anal Toxicol 19 576-580
[2]  
Buronfosse T(2010)Animal poisoning in Europe. Part 2: companion animals Vet J 183 255-259
[3]  
Lorgue G(2009)Rapid identification and determination of the rodenticide valone in serum by high-performance liquid chromatography–tandem mass spectrometry J Anal Toxicol 33 104-108
[4]  
Berny P(2009)An assay for identification and determination of toxic rodenticide valone in serum by ion chromatography–electrospray ionization tandem mass spectrometry with ion trap detector Talanta 78 242-247
[5]  
Caloni F(2016)A modified QuEChERS sample preparation method for simultaneous determination of 62 pesticide residues in edible fungi using gas chromatography–triple quadrupole mass spectrometry Food Anal Methods 9 263-274
[6]  
Croubels S(1993)Simultaneous determination of eight anticoagulant rodenticides in blood serum and liver J Anal Toxicol 17 56-61
[7]  
Sachana M(2014)Analysis of trace bromadiolone and brodifacoum in environmental water samples by ionic liquid ultrasound-assisted dispersive liquid–liquid microextraction and LC-MS/MS Anal Methods 6 5879-5885
[8]  
Vandenbroucke V(1998)Superwarfarin poisoning Arch Intern Med 158 1929-1932
[9]  
Davanzo F(2015)Determination of seven anticoagulant rodenticides in human serum by ultra-performance liquid chromatography-mass spectrometry Anal Methods 7 1884-1889
[10]  
Guitart R(1979)Warfarin and warfarin-alcohol levels in anti-coagulated patients Aust NZ J Med 9 534-537