Review of automatic continuous distraction osteogenesis devices for mandibular reconstruction applications

被引:0
作者
Shahrokh Hatefi
Katayoun Hatefi
Francis Le Roux
Javad Alizargar
Zeinolabedin Behdadipour
Yimesker Yihun
Khaled Abou-El-Hossein
机构
[1] Nelson Mandela University,Precision Engineering Laboratory
[2] Isfahan University of Technology,Department of Electrical and Computer Engineering
[3] Nelson Mandela University,Department of Mechatronics Engineering
[4] National Taipei University of Nursing and Health Sciences,Research Center for Healthcare Industry Innovation
[5] Isfahan University of Medical Sciences,School of Medicine
[6] Wichita State University,Robotics Laboratory, Department of Mechanical Engineering
来源
BioMedical Engineering OnLine | / 19卷
关键词
Automatic continuous distractor; Oral and maxillofacial reconstruction; Distraction osteogenesis; Medical devices;
D O I
暂无
中图分类号
学科分类号
摘要
Distraction osteogenesis (DO) is an emerging method for bone tissue reconstruction. In oral and maxillofacial reconstruction applications, DO is playing an important role as a technique without the need of bone graft. In addition, in a DO treatment procedure, a superior outcome could be achieved compared to conventional reconstruction techniques. Recently, a few automatic continuous distraction osteogenesis (ACDO) devices have been designed and developed to be used in human reconstruction applications. Experiments and animal studies have validated the functionality of the developed ACDO devices. It has shown that by using such ACDO devices in a DO procedure, compared to conventional manual DO methods, superior outcomes could be obtained. However, the application of such ACDO devices is still limited. More research and investigation need to be undertaken to study all requirements of ACDO devices to be used in successful human mandibular DO treatment. It is important to determine all requirements and standards that need to be considered and applied in the design and development of ACDO devices. The purpose of this review paper is to highlight the designed and developed ACDO procedures thus far in terms of their working principles, working parameters, and technical aspects for providing a better perspective of the development progress of ACDO devices for oral and maxillofacial reconstruction applications. In this paper, design principles, device specifications, and working parameters of ACDO devices are compared and discussed. Subsequently, current limitations and gaps have been addressed, and future works for enabling an ultimate automatic DO procedure have been suggested.
引用
收藏
相关论文
共 50 条
  • [41] Design and Analyses of Passive Continuous Distraction Osteogenesis Device for Oral and Maxillofacial Reconstruction
    Hatefi, Shahrokh
    Alizargar, Javad
    Smith, Farouk
    [J]. APPLIED SCIENCES-BASEL, 2024, 14 (20):
  • [42] Reconstruction of Premaxilla with Alveolar Distraction Osteogenesis
    Erverdi, Nejat
    Sar, Cagla
    [J]. INFORMATIONEN AUS ORTHODONTIE UND KIEFERORTHOPAEDIE, 2019, 51 (03): : 187 - 192
  • [43] Helical distraction is superior to linear and circular distraction in mandibular distraction osteogenesis: an in silico study
    Gateno, J.
    Kim, D.
    Bartlett, S.
    Deng, H. H.
    Xu, J.
    Xia, J. J.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2024, 53 (01) : 89 - 99
  • [44] Mandibular reconstruction after excision of recurrent odontogenic keratocyst using a novel mandibular distraction osteogenesis method– a case report
    Haiyun Lin
    Xiaoxia Zhong
    Nuo Zhou
    Xuan-Ping Huang
    [J]. Head & Face Medicine, 19
  • [45] Three-Dimensional Airways Reconstruction in Syndromic Pedriatric Patients Following Mandibular Distraction Osteogenesis
    Spinelli, Giuseppe
    Agostini, Tommaso
    Arcuri, Francesco
    Conti, Marco
    Raffaini, Mirco
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (03) : 650 - 654
  • [46] The BMP signaling and its Smads in mandibular distraction osteogenesis
    Khanal, A.
    Yoshioka, I.
    Tominaga, K.
    Furuta, N.
    Habu, M.
    Fukuda, J.
    [J]. ORAL DISEASES, 2008, 14 (04) : 347 - 355
  • [47] Model surgery prediction for mandibular midline distraction osteogenesis
    Whitman, DH
    Connaughton, B
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 28 (06) : 421 - 423
  • [48] Distraction osteogenesis for correction of post ankylosis mandibular deformities
    Khan, Ahmed
    Fareed, Wamiq Musheer
    Tandon, Parul
    Zafar, Muhammad Sohail
    [J]. JOURNAL OF BIOMEDICAL RESEARCH, 2015, 29 (04): : 332 - 336
  • [49] Clinical Evaluation of Distraction Osteogenesis in the Treatment of Mandibular Hypoplasia
    Al-Mahdi, Akmam H.
    Al-Jumaily, Hassanien Ahmed Hadi
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (01) : E50 - E57
  • [50] Serial bone densitometry during mandibular distraction osteogenesis
    Campisi, P
    Hamdy, RC
    Lauzier, D
    Lessard, ML
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2003, 6 (03) : 225 - 230