Molecularly imprinted polymers based stir bar sorptive extraction for determination of cefaclor and cefalexin in environmental water

被引:0
作者
Jun Peng
Donghao Liu
Tian Shi
Huairu Tian
Xuanhong Hui
Hua He
机构
[1] China Pharmaceutical University,Department of Analytical Chemistry
[2] China Pharmaceutical University,Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education
[3] China Pharmaceutical University,Key Laboratory of Biomedical Functional Materials
来源
Analytical and Bioanalytical Chemistry | 2017年 / 409卷
关键词
Molecularly imprinted polymers; Magnetic carbon nanotubes; Cephalosporins; Environmental water; Stir bar sorption microextraction;
D O I
暂无
中图分类号
学科分类号
摘要
Although stir bar sportive extraction was thought to be a highly efficiency and simple pretreatment approach, its wide application was limited by low selectivity, short service life, and relatively high cost. In order to improve the performance of the stir bar, molecular imprinted polymers and magnetic carbon nanotubes were combined in the present study. In addition, two monomers were utilized to intensify the selectivity of molecularly imprinted polymers. Fourier transform infrared spectroscopy, scanning electron microscopy, and selectivity experiments showed that the molecularly imprinted polymeric stir bar was successfully prepared. Then micro-extraction based on the obtained stir bar was coupled with HPLC for determination of trace cefaclor and cefalexin in environmental water. This approach had the advantages of stir bar sportive extraction, high selectivity of molecular imprinted polymers, and high sorption efficiency of carbon nanotubes. To utilize this pretreatment approach, pH, extraction time, stirring speed, elution solvent, and elution time were optimized. The LOD and LOQ of cefaclor were found to be 3.5 ng · mL–1 and 12.0 ng · mL–1, respectively; the LOD and LOQ of cefalexin were found to be 3.0 ng · mL–1 and 10.0 ng · mL–1, respectively. The recoveries of cefaclor and cefalexin were 86.5 ~ 98.6%. The within-run precision and between-run precision were acceptable (relative standard deviation <7%). Even when utilized in more than 14 cycles, the performance of the stir bar did not decrease dramatically. This demonstrated that the molecularly imprinted polymeric stir bar based micro-extraction was a convenient, efficient, low-cost, and a specific method for enrichment of cefaclor and cefalexin in environmental samples.
引用
收藏
页码:4157 / 4166
页数:9
相关论文
共 143 条
  • [1] DeMuri GP(2012)Clinical practice. Acute bacterial sinusitis in children New Engl J Med 367 1128-34
  • [2] Wald ER(2016)Do we bury antibacterials when launching? Cefaclor example J Pharmaceut Sci 105 1295-300
  • [3] Tomić Z(2016)Pharmacopoeial quality of antimicrobial drugs in southern China Lancet Global Health 4 e300-2
  • [4] Tomas A(2016)Access to effective antimicrobials: a worldwide challenge Lancet 387 168-75
  • [5] Vukmirović S(2016)Efforts to slacken antibiotic resistance: labeling meat products from animals raised without antibiotics in the United States Sci Total Environ 563 1088-94
  • [6] Mikov M(2014)Occurrence and distribution of phthalate esters and pharmaceuticals in Taiwan river sediments J Soil Sediment 15 198-210
  • [7] Horvat O(2016)Removal of pharmaceuticals and personal care products (PPCPs) from wastewater: a review J Environ Manage 182 620-40
  • [8] Tomić N(2009)Simultaneous determination of 10 antibiotic residues in milk by UPLC Chromatographia 70 253-8
  • [9] Pan H(2015)Simultaneous determination of 148 pharmaceuticals and illicit drugs in sewage sludge based on ultrasound-assisted extraction and liquid chromatography-tandem mass spectrometry Anal Bioanal Chem 407 4287-97
  • [10] Luo H(2015)Multi-analyte method for the determination of pharmaceuticals in wastewater samples using solid-phase extraction and liquid chromatography-tandem mass spectrometry Anal Bioanal Chem 407 4229-45