Crack Failure Analysis of a Spiral Drill Collar

被引:0
作者
Jin-lan Zhao
Xiao-liang Bai
Zhao-xi Shen
Le Zhang
Xiaolong Li
Ke Tong
Hui Luan
机构
[1] Tubular Goods Research Center of CNPC,
[2] PetroChina Tuha Oilfield Branch,undefined
来源
Journal of Failure Analysis and Prevention | 2022年 / 22卷
关键词
Drill collar; Crack; Fatigue; Failure; Concentration of stresses;
D O I
暂无
中图分类号
学科分类号
摘要
Cracks were found at the step root of elevator groove of a batch of spiral drill collars before underground service. Configuration dimension detection, nondestructive testing, chemical composition analysis, mechanical properties testing, metallographic examination, XRD, Scanning electron microscope (SEM) were used to comprehensively investigate the failure reason of the spiral drill collar. The results show that configuration dimension, chemical composition, tensile properties, Charpy impact, and hardness test results of the failed spiral drill collar meet the requirements of the spiral drill collar ordering technical standard. The energy spectrum test results of the crack position show that the cracks are not caused by environmental corrosion. The finite element analysis (FEA) method was used to analyze the stress concentration factor of elevator groove and simulated crack location. The FEA calculation results show that the stress concentration factors at the bevel and crack of elevator groove are greater than 2.9 and 10, respectively. The step root of the elevator groove was subjected to complex loads during the underground service, including periodic alternating axial tensile compressive stress, torque, bending and other loads, as well as local uneven friction. The maximum borehole diameter of the well is 444.5 mm, while the diameter of the drill collar is 203.2 mm. There is a large gap between the borehole wall and the drill collar, which is easy to bend the drill string at high speed, accelerating the fatigue crack under the operation of alternating bending stress. Therefore, the cracks at the step root of the elevator groove of this batch of spiral drill collars belonged to fatigue failure originated from the concentration of stresses which was caused by structural mutation at the step root of elevator groove of spiral drill collar and cyclic alternating load action in drilling operation. Suggestions to prevent such failures are proposed.
引用
收藏
页码:1517 / 1525
页数:8
相关论文
共 32 条
[1]  
Zhang J(2016)Facture analysis of drill collar in Ordos gas field and application of fracture prevention technology Sichuan Metall 38 96-100
[2]  
Wang J(2003)Failure analysis on the fracture of the drill collar Phys Exam Test 34 34-37
[3]  
Wang D(2016)Failure analysis of drillstring in petroleum industry: a review Eng Fail Anal 65 74-85
[4]  
Ma F(2022)Dynamic failure analysis and lifetime estimation of Tool-string in rotary drilling system under Torsional-Axial coupled vibrations Eng Fail Anal 134 106037-149
[5]  
Albdiry MT(2018)Fatigue resonant tests on drill collar rotary shouldered connections and critical thread root identification Eng Fail Anal 89 138-735
[6]  
Almensory MF(2019)Cause analysis and mechanism study of cracks in drilling collars Eng Fail Anal 105 727-343
[7]  
Kessai I(2004)Effect of residual stress on ACFM crack measurements in drill collar threaded connections Eng Fail Anal 37 337-273
[8]  
Benammar S(2019)Using a supperficially treated 2025 aluminum alloy drill pipe to delay failure during dynamic loading Eng Fail Anal 104 261-80
[9]  
Doghmane MZ(2017)Downhole vibration causing a drill collar failure and solutions Eng Fail Anal 4 73-1365
[10]  
Santus C(2005)Failure analysis of IEU drill pipe wash out IEU Eng Fail Anal 27 1360-141