Direct determination of arsenic and antimony in naphtha by electrothermal atomic absorption spectrometry with microemulsion sample introduction and iridium permanent modifier

被引:0
|
作者
Ricardo J. Cassella
Bruno Alberto R. S. Barbosa
Ricardo E. Santelli
Alessandra T. Rangel
机构
[1] Universidade Federal Fluminense,Departamento de Química Analítica
[2] Universidade Federal Fluminense,Departamento de Geoquímica
[3] CENPES,PETROBRAS
来源
Analytical and Bioanalytical Chemistry | 2004年 / 379卷
关键词
Electrothermal atomic absorption spectrometry; Naphtha; Arsenic; Antimony; Microemulsion;
D O I
暂无
中图分类号
学科分类号
摘要
This paper reports the determination of arsenic and antimony in naphtha by employing electrothermal atomic absorption spectrometry (ETAAS) as the analytical technique. In order to promote the direct determination of the analytes in the very volatile naphtha, the formation of a microemulsion with different surfactants (Triton X-100 and Brij-35) and different chemical modification strategies were tested. The results indicated that Triton X-100 is the best emulsification agent for naphtha in both As and Sb determination when it is employed at a concentration of 1% w/v in the microemulsion. Under these conditions, the microemulsion was stabile for at least 2 h. By using Brij-35 it was possible to achieve good stability only in the first 15 min. Among all chemical modification approaches investigated (Ir permanent modifier, W-Ir permanent modifier, and Pd modifier), the Ir permanent modifier provided better sensitivity for both analytes and allowed a higher pyrolysis temperature, which decreased the background signals at lower levels. Under the best conditions established in this work, an RSD of 4.6% (20 μg L−1) and a detection limit of 2.7 μg L−1 were observed for arsenic. For antimony, an RSD of 4.0% (20 μg L−1) and a detection limit of 2.5 μg L−1 were obtained. The accuracy of the procedure was assessed by analyzing spiked samples of naphtha from different origins.
引用
收藏
页码:66 / 71
页数:5
相关论文
共 50 条
  • [1] Direct determination of arsenic and antimony in naphtha by electrothermal atomic absorption spectrometry with microemulsion sample introduction and iridium permanent modifier
    Cassella, RJ
    Barbosa, BARS
    Santelli, RE
    Rangel, AT
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (01) : 66 - 71
  • [2] The use of gold nanoparticles as an effective modifier for the determination of arsenic and antimony by electrothermal atomic absorption spectrometry
    Sema Gunduz
    Suleyman Akman
    Asli Baysal
    Mustafa Culha
    Microchimica Acta, 2011, 172 : 403 - 407
  • [3] The use of gold nanoparticles as an effective modifier for the determination of arsenic and antimony by electrothermal atomic absorption spectrometry
    Gunduz, Sema
    Akman, Suleyman
    Baysal, Asli
    Culha, Mustafa
    MICROCHIMICA ACTA, 2011, 172 (3-4) : 403 - 407
  • [4] PERMANENT IRIDIUM MODIFIER FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    RADEMEYER, CJ
    RADZIUK, B
    ROMANOVA, N
    SKAUGSET, NP
    SKOGSTAD, A
    THOMASSEN, Y
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (10) : 739 - 745
  • [5] The use of silver nanoparticles as an effective modifier for the determination of arsenic and antimony by electrothermal atomic absorption spectrometry
    Gunduz, S.
    Akman, S.
    Baysal, A.
    Kahraman, M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (04) : 297 - 300
  • [6] Iridium as permanent modifier in the determination of lead in whole blood and urine by electrothermal atomic absorption spectrometry
    Grinberg, P
    de Campos, RC
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (10) : 1831 - 1843
  • [7] GLUCOSE AS A CHEMICAL MODIFIER FOR THE DETERMINATION OF ANTIMONY AND SELENIUM BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    PEREZCORONA, MT
    DELACALLEGUNTINAS, MB
    MADRID, Y
    CAMARA, C
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (04) : 321 - 324
  • [8] Direct determination of aluminium in serum and urine by electrothermal atomic absorption spectrometry using ruthenium as permanent modifier
    Magalhaes, CG
    Lelis, KLA
    Rocha, CA
    da Silva, JBB
    ANALYTICA CHIMICA ACTA, 2002, 464 (02) : 323 - 330
  • [9] Determination of arsenic in diesel, gasoline and naphtha by graphite furnace atomic absorption spectrometry using microemulsion medium for sample stabilization
    Geisamanda Pedrini Brandão
    Reinaldo Calixto de Campos
    Aderval Severino Luna
    Eustáquio Vinicius Ribeiro de Castro
    Honério Coutinho de Jesus
    Analytical and Bioanalytical Chemistry, 2006, 385
  • [10] Determination of arsenic in diesel, gasoline and naphtha by graphite furnace atomic absorption spectrometry using microemulsion medium for sample stabilization
    Pedrini Brandao, Geisamanda
    Calixto de Campos, Reinaldo
    Severino Luna, Aderval
    Vinicius Ribeiro de Castro, Eustaquio
    Coutinho de Jesus, Honerio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (08) : 1562 - 1569