Experimental investigation on the seismic performance of masonry buildings using shaking table testing

被引:1
作者
Paulo B. Lourenço
Leonardo Avila
Graça Vasconcelos
J.Pedro Pedro Alves
Nuno Mendes
Alfredo C. Costa
机构
[1] University of Minho - Azurém Campus,Department of Civil Engineering, ISISE
[2] National Laboratory for Civil Engineering,NESDE
来源
Bulletin of Earthquake Engineering | 2013年 / 11卷
关键词
Concrete block masonry; Shaking-table tests; Seismic performance; Bed joint reinforcement; Behavior factor;
D O I
暂无
中图分类号
学科分类号
摘要
Masonry buildings worldwide exhibited severe damage and collapse in recent strong earthquake events. It is known that their brittle behavior, which is mainly due to the combination of low tensile strength, large mass and insufficient connection between structural elements, is the main limitation for their structural implementation in residential buildings. A new construction system for masonry buildings using concrete blocks units and trussed reinforcement is presented here and its seismic behavior is validated through shaking table tests. Dynamic tests of two geometrically identical two-story reduced scale (1:2) models have been carried out, considering artificial accelerograms compatible with the elastic response spectrum defined by the Eurocode 8. The first model was reinforced with the new proposed system while the second model was built with unreinforced masonry. The experimental analysis encompasses local and global parameters such as cracking patterns, failure mechanisms, and in-plane and out-of-plane behavior in terms of displacements and lateral drifts from where the global dynamic behavior of the two buildings is analyzed comparatively. Finally, behavior factors for the design recommendations in case of unreinforced masonry are also evaluated.
引用
收藏
页码:1157 / 1190
页数:33
相关论文
共 84 条
[1]  
Abrams DP(2000)Seismic response evaluation for URM buildings J Mason Soc 18 71-78
[2]  
Bairrão R(2009)Shaking table tests of two different reinforcement techniques using polymeric grids on an asymmetric limestone full-scaled structure Eng Struct 31 1321-1330
[3]  
Falcão Silva M(1998)Shaking table tests on 24 simple masonry buildings Earthq Eng Struct D 27 67-90
[4]  
Benedetti D(2010)Seismic performance of an unreinforced masonry building: an experimental investigation Earthq Eng Struct D 39 45-68
[5]  
Carydis P(1994)State of the art report on seismic performance of unreinforced masonry buildings J Struct Eng 120 22-162
[6]  
Pezzoli P(1996)Testing of masonry structures for seismic assessment Earthq Spectra 12 145-462
[7]  
Bothara JK(2006)Seismic loss scenarios based on hazard disaggregation. Application to the metropolitan region of Lisbon, Portugal Assess Manag Earthq Risk 2 449-2596
[8]  
Dhakal RP(2011)In-plane cyclic behaviour of a new reinforced masonry system: experimental results Eng Struct 33 2584-1174
[9]  
Mander JB(2009)Estimation of load reduction factors for clay masonry walls Earthq Eng Struct D 38 1155-462
[10]  
Bruneau M(2010)Experimental analysis of reinforced concrete block masonry walls subjected to in-plane cyclic loading J Struct Eng 136 452-1675