Evaluation of high-cycle fatigue behavior in compact bones at different loading frequencies

被引:0
作者
Mohammad Azadi
Mahshad Farzannasab
机构
[1] Semnan University,Faculty of Mechanical Engineering
来源
Meccanica | 2018年 / 53卷
关键词
High-cycle fatigue; Bovine compact bone; Loading frequency; Scanning electron microscopy;
D O I
暂无
中图分类号
学科分类号
摘要
This article presents the evaluation of the high-cycle fatigue behavior in bovine compact bones under different loading frequencies. For this objective, rotating bending fatigue testing has been utilized at 10, 20 and 30 Hz of the loading frequency. Cylindrical specimens were obtained from the 12-month old bovine compact bone, considering both tibia and femur. Obtained experimental results indicated that averaged fatigue lifetimes of femur was higher than the ones of tibia. Besides, the effect of the loading frequency on the high-cycle fatigue lifetime was not significant. In addition, scanning electron microscopy images predicted brittle fractures for bones with cleavage marks. Failure mechanisms for tibia were reported as the separation of the fiber (osteon) and the matrix, micro-cracks insides the matrix, and micro-cracks of the fiber (osteon). Failure mechanisms for femur were presented as the separation of lamella layers and micro-cracks in the lamella bone.
引用
收藏
页码:3517 / 3526
页数:9
相关论文
共 67 条
  • [1] Azadi M(2016)Optimization of solution temperature and time in nickel-based superalloy of engine turbo-charger based on hardness by design of experiment J Engine Res 43 63-70
  • [2] Iziy M(2016)Modified two-parameter fracture model for bone Eng Fract Mech 174 44-53
  • [3] Marbout A(2014)A methodology for the investigation of toughness and crack propagation in mouse bone J Mech Behav Biomed Mater 39 38-47
  • [4] Azadi M(1981)Uniaxial fatigue of human cortical bone, the influence of tissue physical characteristics Biomechanics 14 461-470
  • [5] Hajiali Mohammadi A(1976)Fatigue life of compact bone effects of microstructure and density Biomechanics 9 211-218
  • [6] Carpinteri A(2015)In vitro evidence of the structural optimization of the human skeletal bones J Biomech 48 787-796
  • [7] Berto F(2016)Effect of torsional loading on compressive fatigue behavior of trabecular bone J Mech Behav Biomech Mater 54 21-32
  • [8] Fortese G(2015)The influence of patient age and bone mineral density on osteotomy fixation stability after hallux valgus surgery Clin Biomech 32 255-260
  • [9] Ronchei C(2007)Fatigue properties of bovine compact bones that have different microstructures Int J Fatigue 29 1039-1050
  • [10] Scorza D(2009)Selection of the implant thread pitch for optimal biomechanical properties: a three-dimensional finite element analysis Adv Eng Softw 40 474-478