Flow injection potentiometric determination of Chlorphenoxamine Hydrochloride

被引:0
作者
Nour T. Abdel-Ghani
Salwa H. Hussein
机构
[1] Cairo University,Faculty of Science, Chemistry Department
来源
Journal of Applied Electrochemistry | 2010年 / 40卷
关键词
Chlorphenoxamine Hydrochloride (Ch-HCl); Ion selective electrode; Flow injection analysis (FIA); Potentiometry; Sodium tetraphenylborate; Phosphotungestic acid and conductimetry;
D O I
暂无
中图分类号
学科分类号
摘要
New Chlorphenoxamine (Ch) ion selective plastic membrane electrodes for both conventional and coated wire types based on the ion associate of Ch-HCl with sodium tetraphenylborate (NaTPB) and phosphotungestic acid (PTA) were prepared. The conventional type electrode was fully characterized in terms of membrane composition, plasticizer, filling solution, life span, pH, ionic strength, temperature. The membranes of optimum compositions were used for the preparation of both graphite and cupper coated wire electrodes. The prepared electrodes were used for the potentiometric determination of the investigated drug in raw material and pharmaceutical preparations under batch and flow injection analysis conditions. The selectivity of the electrodes towards a large number of excipients like inorganic cations, sugars, amino acids and other antihistaminic drugs was tested. Determination of Ch-HCl, the solubility product of the ion associate and the formation constant of the precipitation reaction leading to the ion associate formation of Ch-HCl with NaTPB and PTA were carried out using conductimetric measurements.
引用
收藏
页码:2077 / 2090
页数:13
相关论文
共 50 条
[41]   Application of flow-injection potentiometric system for determination of total concentration of aliphatic carboxylic acids [J].
Mroczkiewicz, Monika ;
Gorski, Lukasz ;
Zamojska-Jaroszewicz, Anna ;
Szewczyk, Krzysztof W. ;
Malinowska, Elzbieta .
TALANTA, 2011, 85 (04) :2047-2052
[42]   Determination of Ondansetron Hydrochloride by a Liquid Membrane Potentiometric Sensor Based on Room Temperature Ionic Liquids [J].
Faridbod, Farnoush ;
Mizani, Farhang ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (08) :10461-10472
[43]   Potentiometric Membrane Sensors for the Selective Determination of Memantine Hydrochloride in Pharmaceutical Preparations [J].
El Nashar, Rasha M. ;
El-Tantawy, Aliaa S. M. ;
Hassan, Saad S. M. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11) :10802-10817
[44]   Potentiometric Membrane Sensors for Determination of Memantine Hydrochloride and Pramipexole Dihydrochloride Monohydrate [J].
Merey, Hanan A. ;
Helmy, Marwa I. ;
Tawakkol, Shereen M. ;
Toubar, Safaa S. ;
Risk, Mohamed S. .
PORTUGALIAE ELECTROCHIMICA ACTA, 2012, 30 (01) :31-43
[45]   Determination of pyridoxine hydrochloride in pharmaceutical preparations by calixarene based potentiometric sensor [J].
Vaze, V. D. ;
Srivastava, A. K. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (01) :177-182
[46]   Potentiometric Determination of Oxymetazoline Hydrochloride Using Modified Carbon Paste Electrodes [J].
Issa, Yousry M. ;
Khalil, Mohamed M. ;
Zayed, Sayed I. M. ;
Mustafa, Naglaa .
PORTUGALIAE ELECTROCHIMICA ACTA, 2021, 39 (05) :381-392
[47]   On-line flow injection solid sample introduction, leaching and potentiometric determination of fluoride in phosphate rock [J].
Sweileh, Jamal A. .
ANALYTICA CHIMICA ACTA, 2007, 581 (01) :168-173
[48]   Potentiometric flow injection sensing system for determination of heparin based on current-controlled release of protamine [J].
Lei, Jiahong ;
Ding, Jiawang ;
Chen, Yan ;
Qin, Wei .
ANALYTICA CHIMICA ACTA, 2015, 858 :60-65
[49]   Flow-injection potentiometric determination of free cadmium ions with a cadmium ion-selective electrode [J].
Trojanowicz, M ;
Alexander, PW ;
Brynn Hibbert, D .
ANALYTICA CHIMICA ACTA, 1998, 370 (2-3) :267-278
[50]   Flow Injection Analysis with Two Parallel Detectors: Potentiometric and Spectrophotometric Determination of Thiols and Ascorbic Acid in Mixture [J].
Martinovic, Anita ;
Cerjan-Stefenovic, Stefica ;
Radic, Njegomir .
JOURNAL OF CHEMICAL METROLOGY, 2008, 2 (01) :1-12