Flow injection potentiometric determination of Chlorphenoxamine Hydrochloride

被引:0
作者
Nour T. Abdel-Ghani
Salwa H. Hussein
机构
[1] Cairo University,Faculty of Science, Chemistry Department
来源
Journal of Applied Electrochemistry | 2010年 / 40卷
关键词
Chlorphenoxamine Hydrochloride (Ch-HCl); Ion selective electrode; Flow injection analysis (FIA); Potentiometry; Sodium tetraphenylborate; Phosphotungestic acid and conductimetry;
D O I
暂无
中图分类号
学科分类号
摘要
New Chlorphenoxamine (Ch) ion selective plastic membrane electrodes for both conventional and coated wire types based on the ion associate of Ch-HCl with sodium tetraphenylborate (NaTPB) and phosphotungestic acid (PTA) were prepared. The conventional type electrode was fully characterized in terms of membrane composition, plasticizer, filling solution, life span, pH, ionic strength, temperature. The membranes of optimum compositions were used for the preparation of both graphite and cupper coated wire electrodes. The prepared electrodes were used for the potentiometric determination of the investigated drug in raw material and pharmaceutical preparations under batch and flow injection analysis conditions. The selectivity of the electrodes towards a large number of excipients like inorganic cations, sugars, amino acids and other antihistaminic drugs was tested. Determination of Ch-HCl, the solubility product of the ion associate and the formation constant of the precipitation reaction leading to the ion associate formation of Ch-HCl with NaTPB and PTA were carried out using conductimetric measurements.
引用
收藏
页码:2077 / 2090
页数:13
相关论文
共 50 条
[31]   Novel biomedical sensors for flow injection potentiometric determination of creatinine in human serum [J].
Hassan, SSM ;
Elnemma, EM ;
Mohamed, AHK .
ELECTROANALYSIS, 2005, 17 (24) :2246-2253
[32]   Determination of orciprenaline using a flow injection analysis system with sequential potentiometric and spectrophotometric detection [J].
El Nashar, Rasha Mohamed .
ANALYTICAL LETTERS, 2008, 41 (06) :949-964
[33]   Flow-Injection Potentiometric Method for the Routine Determination of Chloride: Application to Bread Analysis [J].
Almeida, Sofia A. A. ;
Rebelo, Tania S. C. R. ;
Heitor, Ana M. ;
Oliveira, M. Beatriz P. P. ;
Sales, M. Goreti F. .
CURRENT ANALYTICAL CHEMISTRY, 2010, 6 (04) :277-287
[34]   Sequential determination of chromium(VI) and chromium(III) by potentiometric flow-injection method [J].
Ohura, H ;
Imato, T ;
Matsuo, I ;
Yamasaki, S .
BUNSEKI KAGAKU, 2000, 49 (01) :59-64
[35]   A manganese porphyrin-based sensor for flow-injection potentiometric determination of thiocyanate [J].
Beheshti, Saeed S. ;
Sohbat, Fatemeh ;
Amini, Mohammad K. .
JOURNAL OF PORPHYRINS AND PHTHALOCYANINES, 2010, 14 (02) :158-165
[36]   Determination of Trihexyphenidyl hydrochloride drug in tablets and urine using a potentiometric carbon paste electrode [J].
Abu Shawish, Hazem M. ;
Elhabiby, Mahmoud ;
Abu Aziz, Hadeel S. ;
Saadeh, Salman M. ;
Tbaza, Ahmad .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 235 :18-26
[37]   Selective potentiometric sensors for the determination of butenafine hydrochloride in a cream formulation [J].
Frag, Eman Y. ;
Mohamed, Marwa El badry ;
Mohamed, Gehad G. ;
Ebrahim, Mona Shehatta .
MICROCHEMICAL JOURNAL, 2020, 157
[38]   Potentiometric Determination of Loperamide Hydrochloride by Loperamide PVC Membrane and Nano-Composite Electrodes [J].
Faridbod, F. ;
Mizani, F. ;
Ganjali, M. R. ;
Norouzi, P. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (08) :7643-7654
[39]   A Novel Membrane Sensor for Batch and Flow Injection Potentiometric Determination of Cefazolin Sodium in Pharmaceutical Preparations [J].
Badr, Ibrahim H. A. ;
Saleh, Gamal A. ;
Sayed, Sayed M. ;
El-Deen, Deena A. M. Nour .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (04) :1621-1636
[40]   SEQUENTIAL FLOW-INJECTION POTENTIOMETRIC DETERMINATION OF IODIDE AND IODINE IN POVIDONE-IODINE PHARMACEUTICALS [J].
HASSAN, SSM ;
MARZOUK, SAM .
ELECTROANALYSIS, 1993, 5 (9-10) :855-861