Flow injection potentiometric determination of Chlorphenoxamine Hydrochloride

被引:0
作者
Nour T. Abdel-Ghani
Salwa H. Hussein
机构
[1] Cairo University,Faculty of Science, Chemistry Department
来源
Journal of Applied Electrochemistry | 2010年 / 40卷
关键词
Chlorphenoxamine Hydrochloride (Ch-HCl); Ion selective electrode; Flow injection analysis (FIA); Potentiometry; Sodium tetraphenylborate; Phosphotungestic acid and conductimetry;
D O I
暂无
中图分类号
学科分类号
摘要
New Chlorphenoxamine (Ch) ion selective plastic membrane electrodes for both conventional and coated wire types based on the ion associate of Ch-HCl with sodium tetraphenylborate (NaTPB) and phosphotungestic acid (PTA) were prepared. The conventional type electrode was fully characterized in terms of membrane composition, plasticizer, filling solution, life span, pH, ionic strength, temperature. The membranes of optimum compositions were used for the preparation of both graphite and cupper coated wire electrodes. The prepared electrodes were used for the potentiometric determination of the investigated drug in raw material and pharmaceutical preparations under batch and flow injection analysis conditions. The selectivity of the electrodes towards a large number of excipients like inorganic cations, sugars, amino acids and other antihistaminic drugs was tested. Determination of Ch-HCl, the solubility product of the ion associate and the formation constant of the precipitation reaction leading to the ion associate formation of Ch-HCl with NaTPB and PTA were carried out using conductimetric measurements.
引用
收藏
页码:2077 / 2090
页数:13
相关论文
共 50 条
[21]   A Novel Potentiometric Sensor for Determination of Tramadol Hydrochloride in Biological Samples [J].
Pourhakkak, Parvin ;
Karimi, Mohammad Ali ;
Pourhakkak, Pouran ;
Ardakani, Mohammad Mazloum .
ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (02) :191-200
[22]   Potentiometric determination of cetylpyridinium chloride in oral desinfectants by flow injection analysis [J].
Baptista, PCS ;
Araújo, AN ;
Montenegro, MDBSM .
QUIMICA NOVA, 2003, 26 (04) :475-478
[23]   Potentiometric Determination of Imatinib under Batch and Flow Injection Analysis Conditions [J].
Karim, Shereen E. Abdel ;
El-Nashar, Rasha M. ;
Abadi, Ashraf H. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (10) :9668-9681
[24]   Polymeric Membrane Sensors for Batch and Flow Injection Potentiometric Determination of Procainamide [J].
Alrabiah, Haitham ;
Homoda, Atef M. A. ;
Radowan, Abdellatef A. ;
Ezzeldin, Essam ;
Mostafa, Gamal A. E. .
IEEE SENSORS JOURNAL, 2021, 21 (04) :4198-4208
[25]   Flow injection potentiometric determination of total antioxidant activity of plant extracts [J].
Shpigun, Liliya K. ;
Arharova, Marina A. ;
Brainina, Khena Z. ;
Ivanova, Alla V. .
ANALYTICA CHIMICA ACTA, 2006, 573 :419-426
[26]   Determination of anionic surfactants in environmental waters by flow injection potentiometric analysis [J].
Wang, YJ ;
Guan, S ;
Hao, D ;
Dan, DZ .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (12) :1455-1458
[27]   Construction and performance characterization of ion-selective electrodes for potentiometric determination of phenylpropanolamine hydrochloride applying batch and flow injection analysis techniques [J].
Badawy, SS ;
Youssef, AF ;
Mutair, AA .
ANALYTICA CHIMICA ACTA, 2004, 511 (02) :207-214
[28]   Potentiometric flow-injection system for determination of alkaline phosphatase in human serum [J].
Ogonczyk, Dominika ;
Koncki, Robert .
ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) :194-198
[29]   TUBULAR DETECTORS FOR FLOW-INJECTION POTENTIOMETRIC DETERMINATION OF TETRAFLUOROBORATE IN ELECTROPLATING BATHS [J].
ARAUJO, AN ;
ETXEBARRIA, MB ;
LIMA, JLFC ;
MONTENEGRO, MCBSM ;
OLMOS, RP .
ANALYTICA CHIMICA ACTA, 1994, 293 (1-2) :35-41
[30]   Determination of chloride in admixtures and aggregates for cement by a simple flow injection potentiometric system [J].
Junsomboon, Jaroon ;
Jakmunee, Jaroon .
TALANTA, 2008, 76 (02) :365-368