Flow injection potentiometric determination of Chlorphenoxamine Hydrochloride

被引:0
|
作者
Nour T. Abdel-Ghani
Salwa H. Hussein
机构
[1] Cairo University,Faculty of Science, Chemistry Department
来源
Journal of Applied Electrochemistry | 2010年 / 40卷
关键词
Chlorphenoxamine Hydrochloride (Ch-HCl); Ion selective electrode; Flow injection analysis (FIA); Potentiometry; Sodium tetraphenylborate; Phosphotungestic acid and conductimetry;
D O I
暂无
中图分类号
学科分类号
摘要
New Chlorphenoxamine (Ch) ion selective plastic membrane electrodes for both conventional and coated wire types based on the ion associate of Ch-HCl with sodium tetraphenylborate (NaTPB) and phosphotungestic acid (PTA) were prepared. The conventional type electrode was fully characterized in terms of membrane composition, plasticizer, filling solution, life span, pH, ionic strength, temperature. The membranes of optimum compositions were used for the preparation of both graphite and cupper coated wire electrodes. The prepared electrodes were used for the potentiometric determination of the investigated drug in raw material and pharmaceutical preparations under batch and flow injection analysis conditions. The selectivity of the electrodes towards a large number of excipients like inorganic cations, sugars, amino acids and other antihistaminic drugs was tested. Determination of Ch-HCl, the solubility product of the ion associate and the formation constant of the precipitation reaction leading to the ion associate formation of Ch-HCl with NaTPB and PTA were carried out using conductimetric measurements.
引用
收藏
页码:2077 / 2090
页数:13
相关论文
共 50 条
  • [1] Flow injection potentiometric determination of Chlorphenoxamine Hydrochloride
    Abdel-Ghani, Nour T.
    Hussein, Salwa H.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (12) : 2077 - 2090
  • [2] Flow injection potentiometric determination of clobutinol hydrochloride
    Issa, YM
    Zayed, SIM
    TALANTA, 2006, 69 (02) : 481 - 487
  • [3] Flow injection potentiometric determination of dothiepin hydrochloride
    Ghani, NTA
    El-Nashar, RM
    Bioumy, AA
    ANALYTICAL LETTERS, 2004, 37 (15) : 3237 - 3254
  • [4] Flow injection potentiometric determination of pipazethate hydrochloride
    Abdel-Ghani, NT
    Shoukry, AF
    El Nashar, RM
    ANALYST, 2001, 126 (01) : 79 - 85
  • [5] Flow injection potentiometric determination of amitriptyline hydrochloride
    El-Nashar, RM
    Abdel Ghani, NT
    Bioumy, AA
    MICROCHEMICAL JOURNAL, 2004, 78 (02) : 107 - 113
  • [6] Flow injection potentiometric sensor for determination of phenylpropanolamine hydrochloride
    Issa, Y. M.
    Khalil, M. M.
    Zayed, S. I. M.
    Hussein, Ahmed
    ARABIAN JOURNAL OF CHEMISTRY, 2009, 2 (01) : 41 - 46
  • [7] Flow-injection potentiometric determination of clobutinol hydrochloride in pure state and pharmaceutical preparations
    Abdel-Ghani, N. T.
    El Nashar, R. M.
    Hamed, S. M.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 62 (10) : 977 - 986
  • [8] Flow-injection potentiometric determination of clobutinol hydrochloride in pure state and pharmaceutical preparations
    Abdel-Ghani, N.T.
    El Nashar, R.M.
    Hamed, S.M.
    Journal of Analytical Chemistry, 2007, 62 (10): : 977 - 986
  • [9] Flow-injection potentiometric determination of clobutinol hydrochloride in pure state and pharmaceutical preparations
    N. T. Abdel-Ghani
    R. M. El Nashar
    S. M. Hamed
    Journal of Analytical Chemistry, 2007, 62 : 977 - 986
  • [10] Flow Injection Potentiometric Determination of Terazosin Hydrochloride Using Modified Carbon Paste Electrodes
    Zayed, Sayed I. M.
    Khalil, Mohamed M.
    Issa, Yousry M.
    Khalefa, Huda R.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (05): : 2327 - 2340