An Experimental Determination of the Heat-Transfer Coefficients in the Channels of a Turbogenerator Stator with air and Hydrogen Cooling

被引:0
作者
Antonyuk O.V. [1 ]
Gurevich Z.I. [2 ]
Pafomov Y.V. [1 ]
机构
[1] JSC “Power Machines” —Branch “Elektrosila,”, St. Petersburg
[2] St. Petersburg State Polytechnic University, St. Petersburg
关键词
gas cooling; heat-transfer coefficient; stator; turbogenerator; ventilation channels;
D O I
10.1007/s10749-014-0514-x
中图分类号
学科分类号
摘要
The heat transfer coefficients in the ventilation channels of a turbogenerator stator of new construction, containing slot-shaped axial channels in the teeth, are investigated. Experiments are carried out on a full-scale physical model with air cooling and on a turbogenerator with hydrogen cooling. In the latter case, active heat-transfer sensors, simulating the slot-shaped channels, are built in to the circulation circuit of the cooling gas of a commercial turbogenerator with hydrogen cooling when it was undergoing bench testing. The results of the experiments can be used when designing high-power turbogenerators with total gas cooling. © 2014, Springer Science+Business Media New York.
引用
收藏
页码:236 / 240
页数:4
相关论文
共 3 条
[1]  
Antonjuk O., Kartashova T., Roytgarts M., Series of air-cooled turbogenerators of power up to 410 MV · A,, Int. Conf. POWER-GEN Europe, (2009)
[2]  
Mikheev M.A., Principles of Heat Transfer [in Russian], (1947)
[3]  
Gurevich E.I., Lyamin A.A., Shelemba, “Experience in measuring the temperature of a stator winding with optical fiber sensors in bench tests of a turbogenerator,” Élektr, Stantsii, No, (2010)