Low-cost noninvasive continuous blood pressure monitor

被引:0
作者
de Lorena A.E.S. [1 ]
de Lima R.A. [1 ]
Malagón L.A.G. [1 ]
机构
[1] Polytechnic School of Pernambuco, University of Pernambuco, PE, Recife
关键词
Arduino; Bland–Altman; Blood pressure; Pearson coefficient;
D O I
10.1007/s42600-022-00207-1
中图分类号
学科分类号
摘要
Purpose: A novel design is proposed to measure the Arterial Blood Pressure (BP) using the vascular unloading technique controlling the pressure cuff acting on the air pump speed instead of a servo valve. The BP monitoring in a continuous way allows identifying the hypertension or hypotension states in order to avoid damage of vital organs such as the heart and brain in critically ill patients. Depending on the clinical evaluation, this procedure can be done invasively using an arterial catheter, or noninvasively using, for example, the volume clamp method or vascular unloading technology. In the last case, the finger BP is monitored by a photoplethysmography device coupled to an inflatable cuff controlled by a servo valve to keep constant the diameter of the artery. The cost of commercial devices using this operation principle is relatively high in comparison with noninvasive intermittent BP monitors. Method: A prototype was built based on the Arduino platform, and tested based on the International Protocol of Validation of BP Measurement Instruments in adults. As a result, a low-cost device (components cost around EUR 150) was built. Results: From the Bland–Altman analysis, the mean and standard deviation (SD) were determined as 5.09 ± 12.27 for the Systolic BP, − 1.72 ± 12.56 for the Diastolic BP, and 0.68 ± 11.08 for the Mean BP. Conclusion: Similar results were reported for commercial devices that employ the vascular unload technique controlling the cuff pressure through a servo valve. Then, the proposed device is a low-cost alternative to measure BP with results similar to commercial devices. © 2022, Sociedade Brasileira de Engenharia Biomedica.
引用
收藏
页码:559 / 570
页数:11
相关论文
共 28 条
[1]  
Aagadeesh A.M., Singh N.G., Mahankali S., A comparison of a continuous noninvasive arterial pressure (CNAPTM) monitor with an invasive arterial blood pressure monitor in the cardiac surgical ICU, Ann Card Anaesth, 15, 3, (2012)
[2]  
Akkerman J., Diepeveen M., Ganzevoort W., Van Montfrans G.A., Westerhof B.E., Wolf H., Continuous non-invasive blood pressure monitoring, a validation study of Nexfin in a pregnant population, hypertens, Pregnancy, 28, 2, pp. 230-242, (2009)
[3]  
Ameloot K., Validation study of Nexfin® continuous non-invasive blood pressure monitoring in critically ill adult patients, Minerva, Anestesiol, 80, 12, pp. 1294-1301, (2014)
[4]  
Araghi A., Bander J.J., Guzman J.A., Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?, Crit Care, 10, 2, (2006)
[5]  
Balzer F., Et al., Comparison of the non-invasive Nexfin® monitor with conventional methods for the measurement of arterial blood pressure in moderate risk orthopaedic surgery patients, J Int Med Res, 44, 4, pp. 832-843, (2016)
[6]  
Boehmer R.D., Continuous, real-time, noninvasive monitor of blood pressure: Peňaz methodology applied to the finger, J Clin Monit, 3, 4, pp. 282-287, (1987)
[7]  
Chen Y., Chen J., Development of a noninvasive instantaneous blood pressure measurement device based on volume-compensation method and study of its control algorithm, J Instrum, 15, 8, (2020)
[8]  
EeftinckSchattenkerk D.W., Et al., Nexfin noninvasive continuous blood pressure validated against Riva-Rocci/Korotkoff, Am J Hypertens, 22, 4, pp. 378-383, (2009)
[9]  
Fortin J., Et al., Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops, Comput Biol Med, 36, 9, pp. 941-957, (2006)
[10]  
Fortin J., Et al., A novel art of continuous noninvasive blood pressure measurement, Nat Commun, 12, 1, pp. 1-14, (2021)