Initial distribution volume of glucose as noninvasive indicator of cardiac preload: comparison with intrathoracic blood volume

被引:0
|
作者
Vincenzo Gabbanelli
Simona Pantanetti
Abele Donati
Alessandra Montozzi
Cristiana Carbini
Paolo Pelaia
机构
[1] Università Politecnica delle Marche,Clinica di Anestesia e Rianimazione
来源
Intensive Care Medicine | 2004年 / 30卷
关键词
Measurement technique; Plasma volume; Distribution volume; Cardiac preload; Intrathoracic blood volume;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:2067 / 2073
页数:6
相关论文
共 50 条
  • [1] Initial distribution volume of glucose as noninvasive indicator of cardiac preload: comparison with intrathoracic blood volume
    Gabbanelli, V
    Pantanetti, S
    Donati, A
    Montozzi, A
    Carbini, C
    Pelaia, P
    INTENSIVE CARE MEDICINE, 2004, 30 (11) : 2067 - 2073
  • [2] Initial distribution volume of glucose is correlated with intrathoracic blood volume in hypovolaemia and following volume loading in dogs
    Nakamura, H
    Ishihara, H
    Okawa, H
    Yatsu, Y
    Tsubo, T
    Matsuki, A
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2005, 22 (03) : 202 - 208
  • [3] Comparison of initial distribution volume of glucose and intrathoracic blood volume during hemodynamically unstable states early after esophagectomy
    Ishihara, H
    Nakamura, H
    Okawa, H
    Yatsu, Y
    Tsubo, T
    Hirota, K
    CHEST, 2005, 128 (03) : 1713 - 1719
  • [4] Intrathoracic blood volume index (ITBVI) by single thermodilution - Sensitivity for cardiac preload monitoring
    Reuter, DA
    Felbinger, TW
    Moerstedt, K
    Kilger, E
    Goetz, AE
    ANESTHESIOLOGY, 2000, 93 (3A) : U149 - U149
  • [5] Intrathoracic blood volume index measured by thermodilution for preload monitoring after cardiac surgery
    Reuter, DA
    Felbinger, TW
    Moerstedt, K
    Weis, F
    Schmidt, C
    Kilger, E
    Goetz, AE
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (02) : 191 - 195
  • [6] Intrathoracic blood volume index (ITBVI) by single thermodilution for preload monitoring after cardiac surgery
    Reuter, DA
    Felbinger, TW
    Moerstedt, K
    Kilger, E
    Schuetz, A
    Goetz, AE
    CRITICAL CARE MEDICINE, 2000, 28 (12) : A72 - A72
  • [7] Comparison of the initial distribution volume of glucose and sucrose in volume-challenged dogs
    Takamura, K
    Iwakawa, T
    Sakai, I
    Muraoka, M
    Ishihara, H
    Matsuki, A
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1997, 24 (03): : 144 - 150
  • [8] Assessment of intrathoracic blood volume as an indicator of cardiac preload:: Single transpulmonary thermodilution technique versus assessment of pressure preload parameters derived from a pulmonary artery catheter
    Wiesenack, C
    Prasser, C
    Keyl, C
    Rödïg, G
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (05) : 584 - 588
  • [9] Initial distribution volume of glucose early after cardiac surgery
    Ishihara, H
    ANESTHESIA AND ANALGESIA, 2006, 102 (06): : 1904 - 1904
  • [10] Intrathoracic blood volume measurement: A comparison of transpulmonary lithium indicator dilution with indocyanine green indicator dilution
    Maddison, Ben
    Findlay, George
    Radermacher, Peter
    Hinds, Charles
    Pearse, Rupert M.
    SHOCK, 2008, 29 : 63 - 63