Non-invasive measurements of cardiac output after cardiac surgery

被引:0
|
作者
Ludwik Fedorko
David Preiss
Joseph Fisher
George Djaiani
Jo Carroll
L. Minkovich
Azami Takafumi
George Volgyesi P. Eng.
机构
[1] Toronto General Hospital,Department of Anesthesia & Pain Management
[2] University Health Network,undefined
[3] University of Toronto,undefined
来源
Canadian Journal of Anesthesia | 2005年 / 52卷 / Suppl 1期
关键词
Mixed Venous Oxygen Saturation; Toronto General Hospital; Water Lung Content; Elizabeth Street; Delivery Circuit;
D O I
10.1007/BF03023126
中图分类号
学科分类号
摘要
引用
收藏
页码:A88 / A88
相关论文
共 50 条
  • [1] The Ability Of Four Non-Invasive Cardiac Output Devices To Trend Changes In Cardiac Output After Cardiac Surgery
    Mohindra, R.
    ALKhunaizi, A.
    Al-Fares, A.
    Magder, S. A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [2] Non-invasive ventilation after cardiac surgery
    Cabrini, L.
    Zangrillo, A.
    HEART LUNG AND VESSELS, 2011, 3 (01) : 5 - 7
  • [3] Non-invasive cardiac output monitoring during sinus surgery
    Gollapudy, Suneeta
    Riess, Matthias L.
    JOURNAL OF ANESTHESIA, 2015, 29 (04) : 639 - 639
  • [4] Non-invasive cardiac output monitoring during sinus surgery
    Suneeta Gollapudy
    Matthias L. Riess
    Journal of Anesthesia, 2015, 29 : 639 - 639
  • [5] Non-invasive cardiac output monitoring
    Huber, T
    Segiet, W
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1997, 38 (05): : 233 - 244
  • [6] Comparison of bioreactance non-invasive cardiac output measurements with cardiac magnetic resonance imaging
    Trinkmann, F.
    Schneider, C.
    Michels, J. D.
    Stach, K.
    Doesch, C.
    Schoenberg, S. O.
    Borggrefe, M.
    Saur, J.
    Papavassiliu, T.
    ANAESTHESIA AND INTENSIVE CARE, 2016, 44 (06) : 769 - 776
  • [7] Ultrasonic cardiac output monitor provides effective non-invasive bedside measurements of neonatal cardiac output
    Pliauckiene, Ausrine
    Liubsys, Arunas
    Vankeviciene, Ramune
    Usonis, Vytautas
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (03) : 803 - 807
  • [8] Ultrasonic cardiac output monitor provides effective non-invasive bedside measurements of neonatal cardiac output
    Ausrine Pliauckiene
    Arunas Liubsys
    Ramune Vankeviciene
    Vytautas Usonis
    Journal of Clinical Monitoring and Computing, 2022, 36 : 803 - 807
  • [9] Non-invasive cardiac output monitor validation study in pediatric cardiac surgery patients
    Tirotta, Christopher F.
    Lagueruela, Richard G.
    Madril, Danielle
    Velis, Evelio
    Ojito, Jorge
    Monroe, Daniel
    Aguero, David
    Irizarry, Marysory
    McBride, John
    Hannan, Robert L.
    Burke, Redmond P.
    JOURNAL OF CLINICAL ANESTHESIA, 2017, 38 : 129 - 132
  • [10] Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery
    Knobloch, K
    Lichtenberg, A
    Winterhalter, M
    Rossner, D
    Pichlmaier, M
    Phillips, R
    ANNALS OF THORACIC SURGERY, 2005, 80 (04): : 1479 - 1484