Background: Physical conditions through gait and other functional task are parameters to consider for frailty detection. The aim of the present study is to measure and describe the variability of acceleration, angular velocity and trunk displacement in the ten meter Extended Timed Get-Up-and-Go test in two groups of frail and non-frail elderly people through instrumentation with the iPhone4® smartphone. Secondly, to analyze the differences and performance of the variance between the study groups (frail and non-frail).This is a cross-sectional study of 30 subjects aged over 65 years, 14 frail subjects and 16 non-frail subjects. Results: The highest difference between groups in the Sit-to-Stand and Stand-to-Sit subphases was in the y axis (vertical vector). The minimum acceleration in the Stand-to-Sit phase was -2.69 (-4.17 / -0.96) m/s2 frail elderly versus -8.49 (-12.1 / -5.23) m/s2 non-frail elderly, p < 0.001. In the Gait Go and Gait Come subphases the biggest differences found between the groups were in the vertical axis: -2.45 (-2.77 /-1.89) m/s2 frail elderly versus -5.93 (-6.87 / -4.51) m/s2 non-frail elderly, p < 0.001. Finally, with regards to the turning subphase, the statistically significant differences found between the groups were greater in the data obtained from the gyroscope than from the accelerometer (the gyroscope data for the mean maximum peak value for Yaw movement angular velocity in the frail elderly was specifically 25.60°/s, compared to 112.8°/s for the non-frail elderly, p < 0.05). Conclusions: The inertial sensor fitted in the iPhone4® is capable of studying and analyzing the kinematics of the different subphases of the Extended Timed Up and Go test in frail and non-frail elderly people. For the Extended Timed Up and Go test, this device allows more sensitive differentiation between population groups than the traditionally used variable, namely time. © 2014 Galán-Mercant and Cuesta-Vargas; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 34 条
[1]  
Fried L.P., Tangen C.M., Walston J., Newman A.B., Hirsch C., Gottdiener J., Seeman T., Tracy R., Kop W.J., Burke G., McBurnie M.A., Frailty in older adults, J Gerontol A Biol Sci Med Sci, 56, (2001)
[2]  
Weiss A., Herman T., Plotnik M., Brozgol M., Giladi N., Hausdorff J.M., An instrumented timed up and go: The added value of an accelerometer for identifying fall risk in idiopathic fallers, Physiol Meas, 32, pp. 2003-2018, (2011)
[3]  
Menz H.B., Lord S.R., Fitzpatrick R.C., Age-related differences in walking stability, Age Ageing, 32, pp. 137-142, (2003)
[4]  
Lamoth C.J., Van Deudekom F.J., Van Campen J.P., Appels B.A., De Vries O.J., Pijnappels M., Gait stability and variability measures show effects of impaired cognition and dual tasking in frail people, J Neuroeng Rehabil, 8, (2011)
[5]  
Beauchet O., Dubost V., Herrmann F.R., Kressig R.W., Stride-to-stride variability while backward counting among healthy young adults, J Neuroeng Rehabil, 2, (2005)
[6]  
Berg K.O., Maki B.E., Williams J.I., Holliday P.J., Wood-Dauphinee S.L., Clinical and laboratory measures of postural balance in an elderly population, Arch Phys Med Rehabil, 73, pp. 1073-1080, (1992)
[7]  
Salarian A., Zampieri C., Horak F.B., Carlson-Kuhta P., Nutt J.G., Aminian K., Analyzing 180° turns using an inertial system reveals early signs of progress in Parkinson's Disease, Conf Proc IEEE Eng Med Biol Soc, 2009, pp. 224-227, (2009)
[8]  
Whitney S.L., Marchetti G.F., Schade A., Wrisley D.M., The sensitivity and specificity of the Timed Up & Go and the Dynamic Gait Index for self-reported falls in persons with vestibular disorders, J Vestib Res, 14, pp. 397-409, (2004)
[9]  
Rogers M.A., Phillips J.G., Bradshaw J.L., Iansek R., Jones D., Provision of external cues and movement sequencing in Parkinson's disease, Mot Control, 2, pp. 125-132, (1998)
[10]  
Tinetti M.E., Speechley M., Ginter S.F., Risk factors for falls among elderly persons living in the community, N Engl J Med, 319, pp. 1701-1707, (1988)