Detection and characterization of benign focal liver lesions with multislice CT

被引:0
作者
J. T. Winterer
E. Kotter
N. Ghanem
M. Langer
机构
[1] Department of Diagnostic Radiology,
来源
European Radiology | 2006年 / 16卷
关键词
Liver neoplasms; Diagnostic imaging; Multidetector CT; Spiral computed tomography;
D O I
暂无
中图分类号
学科分类号
摘要
MDCT is a rapidly evolving technique that significantly improves CT imaging for several indications including depiction of focal benign lesions. Imaging mainly profits from improved longitudinal spatial resolution allowing high-quality non-axial reformations and 3D reconstructions and CT angiography as well as rapid accurate multiphase imaging with short breath-holding periods. This review provides an overview of the current status of MDCT with respect to liver imaging and the implications for characterizing benign focal liver lesions. MDCT currently allows the acquisition of thin slices in daily routine diagnostics providing an improved detection rate of small liver lesions. Whereas large benign focal liver lesions exhibit typical patterns of morphology, attenuation and perfusion, which also may be assessed with single-slice scanners, small lesions remain challenging even with MDCT, since the specific criteria for confident diagnosis become more ambiguous. Here, MR imaging provides more detailed information about tissue components and the availability of liver-specific contrast agents, adding further impact to this technique. With respect to dose considerations, the number of necessary multiphase scans as well as the application of very thin collimation should be strictly checked for each patient undergoing MDCT based on the individual clinical situation and question.
引用
收藏
页码:2427 / 2443
页数:16
相关论文
共 261 条
[1]  
Fox SH(1998)Future directions in CT technology Neuroimaging Clin North Am 8 497-513
[2]  
Tanenbaum LN(1986)Benign hepatic tumours and tumour like conditions in men J Clin Pathol 39 183-188
[3]  
Ackelsberg S(1986)Patterns of contrast enhancement of benign and malignant hepatic neoplasms during bolus dynamic and delayed CT Radiology 160 613-618
[4]  
Karhunen PJ(1987)CT of giant cavernous hemangioma AJR 149 83-85
[5]  
Freeny PC(2002)New technical developments in multislice CT RoeFo 174 839-845
[6]  
Marks WM(2003)Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey Eur Radiol 13 1979-1991
[7]  
Scatarige JC(2003)Effective doses in standard protocols for multi-slice CT scanning Eur Radiol 13 1148-1153
[8]  
Kenny JM(2004)[Image quality of thin- and thick-slice MSCT reconstructions in low-contrast objects (liver lesions) with equal doses] Rofo 176 1676-1682
[9]  
Fishman EK(2005)Multi-detector row CT systems and image-reconstruction techniques Radiology 235 756-773
[10]  
Flohr T(2001)Biphasic multi-slice helical CT of the liver: intraindividual comparison of different slice thicknesses for the detection and characterization of focal liver lesions Radiology 217 367-142