Experimental Study on the Influence of Different Transverse Fire Locations on the Critical Longitudinal Ventilation Velocity in Tunnel Fires

被引:1
作者
Wei Zhong
Zhaozhou Li
Tao Wang
Tianshui Liang
Zhen Liu
机构
[1] Zhengzhou University,School of Chemical Engineering and Energy
来源
Fire Technology | 2015年 / 51卷
关键词
Tunnel; Fire; Critical ventilation velocity; Transverse fire location; Longitudinal ventilation;
D O I
暂无
中图分类号
学科分类号
摘要
A set of fire experiments were conducted in a small-scale tunnel of length 8 m, width 1 m and height 0.5 m, to investigate the influence of different transverse fire locations on the critical longitudinal ventilation velocity for suppressing the smoke backflow in tunnel fire. Six pool sizes were separately used in the experiment, and the burning rate of these pool fires were in the range of 0.05–0.5 g/s. Experimental results showed that for ethanol pool fire, the mass burning rate of fire source kept almost unchanged in the process of the fire moving from the central tunnel to the sidewall, while the maximum temperature rise under the ceiling increased exponentially with the decrease of the distance between the fire and the sidewall, and reached about 1–1.7 times of the fire at the longitudinal centerline. Because critical longitudinal ventilation velocity is associated with the temperature in the impingement area, the critical velocity was investigated in the experiments as well. The dimensionless critical velocity varied with the burning rate, and located in the range of 0.1–0.24 in the experiment. When fires occurred at the center of the tunnel, there was a good agreement between the critical longitudinal ventilation velocity and the model of Wu. The critical longitudinal ventilation velocity would increase exponentially with the decrease of the distance between the fire and the sidewall. When fires neighbored sidewall, the critical longitudinal ventilation velocity was agreed well with the value calculated using the “mirror” method based on Wu’s model.
引用
收藏
页码:1217 / 1230
页数:13
相关论文
共 77 条
[1]  
Carvel RO(2004)The Influence of tunnel geometry and ventilation on the heat release rate of a fire Fire Technol 40 5-26
[2]  
Beard AN(2008)Fire dynamics simulator (Version 4.0) simulation for tunnel fire scenarios with forced, transient, longitudinal ventilation flows Fire Technol 44 137-166
[3]  
Jowitt PW(2004)How many people are exposed to sublethal fire smoke Fire Technol 40 101-116
[4]  
Kim E(2013)Influence of cross-sectional area and aspect ratio of shaft on natural ventilation in urban road tunnel Int J Heat Mass Transf 67 420-431
[5]  
Woycheese JP(2005)Fire spread between vehicles in tunnels: effects of tunnel size, longitudinal ventilation and vehicle spacing Fire Technol 41 271-304
[6]  
Dembsey NA(2005)An experimental study of the effect of the aspect ratio on the critical velocity in longitudinal ventilation tunnel fires J Fire Sci 23 119-138
[7]  
Hall JR(2013)A new approach for prioritization in fuzzy AHP with an application for selecting the best tunnel ventilation system Int J Adv Manuf Technol 68 2589-2599
[8]  
Ji J(2014)Position of maximum ceiling temperature in a tunnel fire Fire Technol 50 889-905
[9]  
Han JY(1995)Control of smoke flow in tunnel fires Fire Saf J 25 305-322
[10]  
Fan CG(2000)Control of smoke flow in tunnel fires using longitudinal ventilation systems—a study of the critical velocity Fire Saf J 35 363-390