Bone densitometry: influence of prosthetic design and hydroxyapatite coating on regional adaptive bone remodelling

被引:0
|
作者
L. Rosenthall
J. D. Bobyn
M. Tanzer
机构
[1] McGill University Health Center,
[2] MGH,undefined
[3] 1650 Cedar Avenue,undefined
[4] Montreal,undefined
[5] Canada H3G 1A4 e-mail: rosenthl@rad.mgh.mcgill.ca; Tel.: +1-514-934-8081,undefined
[6] Fax: +1-514-934-8370,undefined
[7] Division of Orthopaedic Surgery,undefined
[8] Jo Miller Orthopaedic Research Center,undefined
[9] McGill University Health Center,undefined
[10] Montreal,undefined
[11] Canada,undefined
来源
International Orthopaedics | 1999年 / 23卷
关键词
Bone Mineral Density; Hydroxyapatite; Femoral Component; Porous Surface; Bone Mineral Density Measurement;
D O I
暂无
中图分类号
学科分类号
摘要
The objective of this prospective study was to determine if bone densitometry can detect disparities in regional adaptive bone remodelling surrounding the cementless porous-coated femoral component of a hip prosthesis in two titanium alloy implants of different design . These prostheses were the S-ROM™ (n=69) and the Multilock™ (n=65). The Multilock™ implants consisted of two groups; 25 had a 50 micron layer of hydroxyapatite (HA) sprayed over the porous surface of the femoral component and the remaining 40 femoral components were not coated with HA. Densitometry was performed with dual energy X-ray absorptiometry (DXA) utilizing the LUNAR ORTHO™ software to analyse the seven Gruen zones. Bone mineral density measurements were obtained within a week of surgery as a baseline reference and at 6, 12, 24, 36 and 48 months thereafter. At 6 months there was significant mineral loss in all Gruen zones in the three prostheses. By 48 months there were differences in mineral loss between the three prostheses. In the zones adjacent to the porous surface, predominantly zones 1 and 7, the S-ROM™ exhibited 60% less mineral loss than the Multilock™ in zone 1, and there was no significant difference in zone 7. Compared to the Multilock-HA, the S-ROM lost 35% less mineral in zone 1, but the Multilock™ lost 70% less mineral than the S-ROM™ in zone 7. The Multilock-HA lost 37% and 75% less mineral than the Multilock in zones 1 and 7, respectively, i.e., hydroxyapatite coating tended to preserve bone stalk. Using the Gruen zone area measurements provided by the software, the S-ROM had significantly greater bone resorption in zone 7 at 24 months than either of the Multilocks, which did not differ from each other. In conclusion, DXA has shown differences in periprosthetic adaptive bone remodelling between implants of different design and composition as a function of time.
引用
收藏
页码:325 / 329
页数:4
相关论文
共 50 条
  • [21] Bone remodelling simulation:: a tool for implant design
    García, JM
    Doblaré, M
    Cegoñino, J
    COMPUTATIONAL MATERIALS SCIENCE, 2002, 25 (1-2) : 100 - 114
  • [22] Strain adaptive bone remodelling in total joint replacement
    Draenert, KD
    Draenert, YL
    Krauspe, R
    Bettin, D
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) : 12 - 27
  • [23] Hydroxyapatite coating by dipping method, and bone bonding strength
    Li, TT
    Lee, JH
    Kobayashi, T
    Aoki, H
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1996, 7 (06) : 355 - 357
  • [24] Influence of bone marrow characteristic and trabecular bone morphology on bone remodelling process with FSI approach
    Rabiatul, A. A. R.
    Rianti, Devi
    Fatihhi, S. J.
    Saad, Amir Putra Md
    Zakaria, Zulfadzli
    Yuliati, Anita
    Harun, M. N.
    Kadir, M. R. A.
    Ochsner, Andreas
    Kamarul, Tunku
    Saqr, Khalid M.
    Syahrom, Ardiyansyah
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2022, 236 (08) : 1682 - 1695
  • [25] OUANTITATIVE ANALYSIS OF THE BONE-HYDROXYAPATITE COATING INTERFACE
    STEA, S
    VISENTIN, M
    SAVARINO, L
    DONATI, ME
    PIZZOFERRATO, A
    MORONI, A
    CAJA, V
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1995, 6 (08) : 455 - 459
  • [26] Community bone densitometry: Influence on treatment initiation and compliance?
    Dugard, M. N.
    Jones, T.
    Penry, K.
    Ryan, T. D.
    Williams, H. C.
    Davie, M. W. J.
    CALCIFIED TISSUE INTERNATIONAL, 2007, 80 : S123 - S124
  • [27] Compton scatter densitometry in bone: influence of the anatomical site
    Koligliatis, T
    Kalef-Ezra, J
    Speller, RD
    Mooney, MJ
    Litsas, J
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 1998, 14 (02): : 73 - 78
  • [28] Bone remodelling: A process of non-adaptive and adaptive mass supply
    Faust, G
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING - 3, 2001, : 141 - 146
  • [29] DTPA THERAPY FOR CHELATION OF PU-239 IN BONE - INFLUENCE OF BONE REMODELLING
    JAMES, AC
    TAYLOR, DM
    HEALTH PHYSICS, 1971, 21 (01): : 31 - +
  • [30] Mechanobiochemical bone remodelling around an uncemented acetabular component: influence of bone orthotropy
    Ceby Mullakkara Saviour
    Basil Mathai
    Sanjay Gupta
    Medical & Biological Engineering & Computing, 2024, 62 : 1717 - 1732