Soft Copy versus Hard Copy Reading in Digital Mammography

被引:0
|
作者
Silvia Obenauer
Klaus-Peter Hermann
Katharina Marten
Susanne Luftner-Nagel
Dorit von Heyden
Per Skaane
Eckhardt Grabbe
机构
[1] Georg-August-University Göttingen,Department of Diagnostic Radiology
[2] Ullevaal University Hospital,Department of Radiology
来源
Journal of Digital Imaging | 2003年 / 16卷
关键词
Soft copy reading; hard copy reading; digital mammography;
D O I
暂无
中图分类号
学科分类号
摘要
The objective of this study was to compare soft copy reading at a mammography work station with hard copy reading of full-field digital mammographic images. Mammograms of 60 patients (n = 29 malignant, n = 31 benign) performed with full-field digital mammography (Senographe 2000D, GE, Buc, France) were evaluated. Reading was performed based on hard copy prints (Scopix, Agfa, Leverkusen, Germany) and on 2 k × 2.5 k high-resolution monitors (Sun Ultra 60, Sun Microsystems, Palo Alto, California, USA). Four readers with different levels of experience in mammography categorized the mammograms according to the BI-RADS classification. The comparative study was performed by four readers, and at least 2 months elapsed between the reading sessions. Postprocessing, of course, was available only at the work station (windowing and leveling, zooming, inversion). Sensitivity, specificity, and positive predictive value were evaluated. Diagnostic accuracy of the evaluation was determined. Sensitivity for malignant lesions in hard copy versus soft copy reading was 97% vs 90%, 97% vs 97%, 93% vs 97%, and 76% vs 76% for the four readers, respectively. Specificity was 52% vs 68%, 58% vs 74%, 65% vs 48%, and 61% vs 68%. Accuracy for the classification of malignant lesions according to the BI-RADS categories showed no difference between hard copy and soft copy reading. Soft copy reading is possible with the available system and enables radiologists to use the advantages of a digital system.
引用
收藏
页码:341 / 344
页数:3
相关论文
共 50 条
  • [1] Soft copy versus hard copy reading in digital mammography
    Obenauer, S
    Hermann, KP
    Marten, K
    Luftner-Nagel, S
    von Heyden, D
    Skaane, P
    Grabbe, E
    JOURNAL OF DIGITAL IMAGING, 2003, 16 (04) : 341 - 344
  • [2] Comparison of Soft-copy and Hard-copy Reading for Full-Field Digital Mammography
    Nishikawa, Robert M.
    Acharyya, Suddhasatta
    Gatsonis, Constantine
    Pisano, Etta D.
    Cole, Elodia B.
    Marques, Helga S.
    D'Orsi, Carl J.
    Farria, Dione M.
    Kanal, Kalpana M.
    Mahoney, Mary C.
    Rebner, Murray
    Staiger, Melinda J.
    RADIOLOGY, 2009, 251 (01) : 41 - 49
  • [3] HARD COPY WITH/VERSUS SOFT COPY
    KAZAN, B
    SID INTERNATIONAL SYMPOSIUM DIGEST OF TECHNICAL PAPERS, 1971, 11 (MAY): : 48 - &
  • [4] Soft copy digital mammography
    Kim, HH
    KOREAN JOURNAL OF RADIOLOGY, 2005, 6 (04) : 206 - 207
  • [5] Development of Digital Phantom for Digital Mammography with Soft-Copy Reading
    Shinohara, Norimitsu
    Horita, Katsuhei
    Endo, Tokiko
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 68 - 74
  • [6] Soft Copy Display Requirements for Digital Mammography
    Bradley M. Hemminger
    Journal of Digital Imaging, 2003, 16 : 292 - 305
  • [7] Soft copy display requirements for digital mammography
    Hemminger, BM
    JOURNAL OF DIGITAL IMAGING, 2003, 16 (03) : 292 - 305
  • [8] Observer variability in screen-film mammography versus full-field digital mammography with soft-copy reading
    Per Skaane
    Felix Diekmann
    Corinne Balleyguier
    Susanne Diekmann
    Jean-Charles Piguet
    Kari Young
    Michael Abdelnoor
    Loren Niklason
    European Radiology, 2008, 18
  • [9] Observer variability in screen-film mammography versus full-field digital mammography with soft-copy reading
    Skaane, Per
    Diekmann, Felix
    Balleyguier, Corinne
    Diekmann, Susanne
    Piguet, Jean-Charles
    Young, Kari
    Abdelnoor, Michael
    Niklason, Loren
    EUROPEAN RADIOLOGY, 2008, 18 (06) : 1134 - 1143
  • [10] Comparison of interpretation times for screening exams between soft copy full-field digital mammography and hard copy screen-film mammography
    Solari, M
    Berns, EA
    Hendrick, RE
    Wolfman, JA
    Willis, W
    Segal, L
    DeLeon, P
    Benjamin, S
    Reddy, D
    Mendelson, E
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 11 - 11