Airborne mineral dust measurement using an integrated microfluidic device

被引:0
作者
Fan Liu
Yu Han
Li Du
Pengfei Huang
Jiang Zhe
机构
[1] University of Akron,Department of Mechanical Engineering
[2] Beijing University of Technology,College of Mechanical Engineering and Applied Electronics Technology
来源
Microfluidics and Nanofluidics | 2016年 / 20卷
关键词
Mineral dust measurement; Size distribution; Impinger; Multichannel Coulter counter;
D O I
暂无
中图分类号
学科分类号
摘要
We present a new airborne mineral dust measurement instrument consisting of a high-efficiency collection system and a microfluidic multichannel Coulter counter. Simulating a complete airborne mineral dust measurement procedure, silica microparticles are uniformly dispersed into a chamber and are subsequently collected into liquid sample of a vacuum-driven impinger; the liquid sample is then pumped to and analyzed in the multichannel Coulter counter to obtain size and concentration information. The accuracy of sizing and counting capabilities of the multichannel Coulter counter is proved by testing the mixture of standard 1.0-, 2.0- and 5.0-µm microparticles. Next, soda lime glass microparticles ranging from 2 to 10 µm, as a mineral dust simulant, are collected and analyzed. Collection efficiency is demonstrated to be 94 %. Accurate size distribution and concentration of microparticles are obtained from the multichannel Coulter counter. With its simple structure and operation, the mineral dust measurement instrument provides reliable analysis results and is promising for real-time, on-site airborne mineral dust monitoring.
引用
收藏
相关论文
共 99 条
[11]  
Chung A(2004)On the equivalence of gravimetric PM data with TEOM and beta-attenuation measurements J Aerosol Sci 35 1135-859
[12]  
Chang DPY(1992)Microscopic characterization of particle size and shape: an inexpensive and versatile method Pharm Res 9 856-232
[13]  
Kleeman MJ(1982)Occupational exposure and 12-year spirometric changes among Paris area workers Br J Ind Med 39 221-226
[14]  
Davidson CI(2006)Particle size distributions and concentrations of airborne endotoxin using novel collection methods in homes during the winter and summer seasons Indoor Air 16 216-4298
[15]  
Phalen RF(1999)Long-term sampling of airborne bacteria and fungi into a non-evaporating liquid Atmos Environ 33 4291-957
[16]  
Solomon PA(2000)The effect of refractive index on size distributions and light scattering coefficients derived from optical particle counters J Aerosol Sci 31 945-67
[17]  
DeBlois RW(2005)Levels of selected metals in ambient air PM10 in an urban site of Zaragoza (Spain) Environ Res 99 58-907
[18]  
Duzgoren-Aydin NS(1976)Atmospheric particulate mass measurement with beta attenuation mass monitor Environ Sci Technol 10 904-651
[19]  
Giugliano M(2005)Biological dust exposure in the workplace is a risk factor for chronic obstructive pulmonary disease Thorax 60 645-614
[20]  
Lonati G(2005)Airborne nanostructured particles and occupational health J Nanoparticle Res 7 587-1999