Asymmetric time-dependent model for the dynamic finger arterial pressure–volume relationship

被引:0
作者
Jaak Talts
Rein Raamat
Kersti Jagomägi
机构
[1] University of Tartu,Department of Physiology
来源
Medical and Biological Engineering and Computing | 2006年 / 44卷
关键词
Modelling; System identification; Pressure–volume relationship; Peripheral arterial compliance; Blood pressure; Photoplethysmography;
D O I
暂无
中图分类号
学科分类号
摘要
The volumetric pulses in the finger PPG signal appear as an information source for several indirect measurement methods. In this study we modelled transformation of pressure pulses into volume pulses in a wide transmural pressure range. The noninvasive finger arterial pressure and photoplethysmographic (PPG) signals were simultaneously registered in 13 healthy subjects while the pressure in the PPG cuff ramped up and down. The nonlinearity of the pressure–volume (P–V) relationship was modelled by an asymmetric function, consisting of two arctangents, each for a different pressure region. The time dependency was described by the first order lag. The disturbing effect of slow creeps in the PPG signal was suppressed by an equal filtering of the measured and model-predicted signal. The differences between the two estimates of the subject’s P–V relationship for the increasing and decreasing cuff pressure were small thus showing the repeatability of this method, which can be used for the characterization of individual finger arterial behaviour as well as its changes.
引用
收藏
页码:829 / 834
页数:5
相关论文
共 62 条
[1]  
Allen J(1999)Modelling the relationship between peripheral blood pressure and blood volume pulses using linear and neural network system identification techniques Physiol Meas 20 287-301
[2]  
Murray A(1997)Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure Med Biol Eng Comput 35 271-278
[3]  
Baker PD(1996)Contribution of collagen, elastin, and smooth muscle to in vivo human brachial artery wall stress and elastic modulus Circulation 94 3263-3270
[4]  
Westenskow DR(1999)In vivo human brachial artery elastic mechanics: effects of smooth muscle relaxation Circulation 100 41-47
[5]  
Kück K(2005)Right–left correlation of the sympathetically induced fluctuations of the photoplethysmographic signal in diabetic and non-diabetic subjects Med Biol Eng Comput 43 252-257
[6]  
Bank AJ(1994)Theory of the oscillometric maximum and the systolic and diastolic detection ratios Ann Biomed Eng 22 88-96
[7]  
Wang H(2001)Progression of large artery structural and functional alterations in type I diabetes Diabetologia 44 203-208
[8]  
Holte JE(1988)Forearm arterial pressure-volume relationships in man Clin Phys Physiol Meas 9 123-132
[9]  
Bank AJ(2002)Dynamic blood pressure–volume relationship estimated in man, in vivo IFMBE Proc 2 47-48
[10]  
Kaiser DR(2005)Echocardiographic assessment of aortic elastic properties with automated border detection in an ICU: in vivo application of the arctangent Langewouters model Am J Physiol Heart Circ Physiol] 288 H2504-H2511