Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions

被引:0
作者
Danián Alejandro López
Alicia Durán
Silvia Marcela Ceré
机构
[1] Instituto de Investigaciones en Ciencia y Tecnología de Materiales (INTEMA),
[2] UNMdP-CONICET,undefined
[3] Instituto de Cerámica y Vidrio,undefined
[4] CSIC,undefined
来源
Journal of Materials Science: Materials in Medicine | 2008年 / 19卷
关键词
Corrosion Product; Electrochemical Impedance Spectroscopy; Simulated Body Fluid; Passive Film; Infection Condition;
D O I
暂无
中图分类号
学科分类号
摘要
Titanium and cobalt alloys, as well as some stainless steels, are among the most frequently used materials in orthopaedic surgery. In industrialized countries, stainless steel devices are used only for temporary implants due to their lower corrosion resistance in physiologic media when compared to other alloys. However, due to economical reasons, the use of stainless steel alloys for permanent implants is very common in developing countries. The implantation of foreign bodies is sometimes necessary in the modern medical practice. However, the complex interactions between the host and the can implant weaken the local immune system, increasing the risk of infections. Therefore, it is necessary to further study these materials as well as the characteristics of the superficial film formed in physiologic media in infection conditions in order to control their potential toxicity due to the release of metallic ions in the human body. This work presents a study of the superficial composition and the corrosion resistance of AISI 316L stainless steel and the influence of its main alloying elements when they are exposed to an acidic solution that simulates the change of pH that occurs when an infection develops. Aerated simulated body fluid (SBF) was employed as working solution at 37 °C. The pH was adjusted to 7.25 and 4 in order to reproduce normal body and disease state respectively. Corrosion resistance was measured by means of electrochemical impedance spectroscopy (EIS) and anodic polarization curves.
引用
收藏
页码:2137 / 2144
页数:7
相关论文
共 58 条
[1]  
SHIH CH.-CH.(2004)undefined Corros. Sci. 46 427-undefined
[2]  
SHIH CH.-M.(2002)undefined Mater. Charact. 49 73-undefined
[3]  
SU Y.-Y.(1999)undefined Clin. Orthop. Relat. Res. 358 173-undefined
[4]  
SU L. H. J.(1998)undefined J. Joint Bone Surg. 80 268-undefined
[5]  
CHANG M.-S.(2004)undefined Electrochim. Acta 49 2113-undefined
[6]  
LIN S.-J.(1990)undefined J. Biomed. Mater. Res. 24 721-undefined
[7]  
GURAPPA I.(1991)undefined ISIJ Int. 31 134-undefined
[8]  
JACOBS J.(1982)undefined Corrosion 38 46-undefined
[9]  
SILVERTON C.(1986)undefined J. Electrochem. Soc. 133 2459-undefined
[10]  
HALLAB N.(2005)undefined Corros. Sci. 47 581-undefined