Wearable Biosensors to Detect Physiologic Change During Opioid Use

被引:53
作者
Carreiro S. [1 ]
Wittbold K. [1 ]
Indic P. [2 ]
Fang H. [3 ]
Zhang J. [3 ]
Boyer E.W. [1 ]
机构
[1] Department of Emergency Medicine, Division of Medical Toxicology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, 01605, MA
[2] Department of Neurology, University of Massachusetts Medical School, Worcester, MA
[3] Department of Quantitative Health Sciences, University of Massachusetts Medical School, Worcester, MA
关键词
Biometrics; Biosensors; Opioids; Signal Processing; Wearables;
D O I
10.1007/s13181-016-0557-5
中图分类号
学科分类号
摘要
Introduction: Opioid analgesic use is a major cause of morbidity and mortality in the US, yet effective treatment programs have a limited ability to detect relapse. The utility of current drug detection methods is often restricted due to their retrospective and subjective nature. Wearable biosensors have the potential to improve detection of relapse by providing objective, real time physiologic data on opioid use that can be used by treating clinicians to augment behavioral interventions. Methods: Thirty emergency department (ED) patients who were prescribed intravenous opioid medication for acute pain were recruited to wear a wristband biosensor. The biosensor measured electrodermal activity, skin temperature and locomotion data, which was recorded before and after intravenous opioid administration. Hilbert transform analyses combined with paired t-tests were used to compare the biosensor data A) within subjects, before and after administration of opioids; B) between subjects, based on hand dominance, gender, and opioid use history. Results: Within subjects, a significant decrease in locomotion and increase in skin temperature were consistently detected by the biosensors after opioid administration. A significant change in electrodermal activity was not consistently detected. Between subjects, biometric changes varied with level of opioid use history (heavy vs. nonheavy users), but did not vary with gender or type of opioid. Specifically, heavy users demonstrated a greater decrease in short amplitude movements (i.e. fidgeting movements) compared to non-heavy users. Conclusion: A wearable biosensor showed a consistent physiologic pattern after ED opioid administration and differences between patterns of heavy and non-heavy opioid users were noted. Potential applications of biosensors to drug addiction treatment and pain management should be studied further. © 2016, American College of Medical Toxicology.
引用
收藏
页码:255 / 262
页数:7
相关论文
共 22 条
[1]  
Prescription overdose in the United States: fact sheet, (2015)
[2]  
Fletcher R., Tam S., Omojola O., Redemske R., Kwan J., Wearable sensor platform and mobile application for use in cognitive behavioral therapy for drug addiction and PTSD, Conf Proc IEEE Eng Med Biol Soc, pp. 1802-1805, (2011)
[3]  
Addressing prescription drug abuse in the United States, (2014)
[4]  
Principles of Drug Addiction Treatment [Internet], (2012)
[5]  
Fishman S.M., Wilsey B., Yang J., Reisfield G.M., Adherence monitoring and drug surveillance in chronic opioid therapy, J Pain Symptom Manag, 20, 4, pp. 293-307, (2000)
[6]  
Poh M.-Z., Swenson N.C., Picard R.W., A wearable sensor for unobtrusive, long-term assessment of electrodermal activity, IEEE Trans Biomed Eng, 57, 5, pp. 1243-1252, (2010)
[7]  
Fletcher R., Tam S., Omojola O., Redemske R., Kwan J. Wearable sensor platform and mobile application for use in cognitive behavioral therapy for drug addiction and PTSD, pp. 1-4, (2011)
[8]  
Boyer E.W., Fletcher R., Fay R.J., Smelson D., Ziedonis D., Picard R.W., Preliminary efforts directed toward the detection of craving of illicit substances: the iHeal project, J Med Toxicol, 8, 1, pp. 5-9, (2012)
[9]  
Boyer E.W., Smelson D., Fletcher R., Ziedonis D., Picard R.W., Wireless technologies, ubiquitous computing and mobile health: application to drug abuse treatment and compliance with HIV therapies, J Med Toxicol, 6, 2, pp. 212-216, (2010)
[10]  
Indic P., Murray G., Maggini C., Amore M., Meschi T., Borghi L., Multi-scale motility amplitude associated with suicidal thoughts in major depression. de Erausquin GA, editor, PLoS ONE, 7, 6, (2012)