Development of Multilayer Readout Wiring TES Calorimeter for Future X-ray Missions

被引:0
|
作者
S. Yamada
Y. Ezoe
Y. Ishisaki
T. Ohashi
N. Iijima
K. Mitsuda
K. Nagayoshi
H. Akamatsu
T. Morooka
K. Tanaka
机构
[1] RIKEN,Nishina Center
[2] Tokyo Metropolitan University,Department of Physics
[3] ISAS/JAXA,undefined
[4] SRON,undefined
[5] Seiko Instruments Inc,undefined
[6] Hitachi High-Tech Science Corporation,undefined
来源
Journal of Low Temperature Physics | 2014年 / 176卷
关键词
TES; X-ray astronomy; Multilayer wiring;
D O I
暂无
中图分类号
学科分类号
摘要
We have fabricated multilayer readout wiring transition edge sensors (TES), which enable us to realize both large effective area and high-energy resolution for future X-ray astrophysical missions, such as diffuse intergalactic oxygen surveyor. By sandwiching a SiO2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_2$$\end{document} insulation layer between Al superconducting signal and return lines, self/mutual inductances and self fielding of bias leads are expected to be reduced. We fabricated 4×4\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$4\times 4$$\end{document} and 20×20\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$20\times 20$$\end{document} TES array on the multilayer wiring and tested their performance. Under the low temperature condition, several pixels in the TES array showed sharp superconducting transitions at around ∼\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\sim $$\end{document}300 mK. We also succeeded in detecting X-ray signals from the 4×4\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$4\times 4$$\end{document} TES, contrary to the previous results of 20×20\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$20\times 20$$\end{document} TES. We further investigated the reasons for the differences between the 4×4\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$4\times 4$$\end{document} TES and the 20×20\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$20\times 20$$\end{document} TES, and present future plans for improving the multilayer TES array fabrication.
引用
收藏
页码:310 / 315
页数:5
相关论文
共 50 条
  • [1] Development of Multilayer Readout Wiring TES Calorimeter for Future X-ray Missions
    Yamada, S.
    Ezoe, Y.
    Ishisaki, Y.
    Ohashi, T.
    Iijima, N.
    Mitsuda, K.
    Nagayoshi, K.
    Akamatsu, H.
    Morooka, T.
    Tanaka, K.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2014, 176 (3-4) : 310 - 315
  • [2] Development of Multilayer Readout Wiring for Large-Format TES X-Ray Microcalorimeter Arrays
    Ezoe, Yuichiro
    Ishisaki, Yoshitaka
    Oishi, Shihoko
    Abe, Yuki
    Ohashi, Takaya
    Yoshitake, Hiroshi
    Sekiya, Norio
    Mitsuda, Kazuhisa
    Morooka, Toshimitsu
    Tanaka, Keiichi
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 246 - 249
  • [3] Development of Superconducting Multilayer Wiring for Large Arrays of TES X-Ray Microcalorimeters
    Oishi, S.
    Ishisaki, Y.
    Ezoe, Y.
    Abe, Y.
    Enokijima, Y.
    Hosoya, R.
    Ohashi, T.
    Mitsuda, K.
    Morooka, T.
    Tanaka, K.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2012, 167 (3-4) : 220 - 225
  • [4] Development of Superconducting Multilayer Wiring for Large Arrays of TES X-Ray Microcalorimeters
    S. Oishi
    Y. Ishisaki
    Y. Ezoe
    Y. Abe
    Y. Enokijima
    R. Hosoya
    T. Ohashi
    K. Mitsuda
    T. Morooka
    K. Tanaka
    Journal of Low Temperature Physics, 2012, 167 : 220 - 225
  • [5] Development of a TES micro calorimeter system for the future X-ray mission
    Ishisaki, Y
    Yamasaki, N
    Ohashi, T
    Kagei, T
    Miyazaki, T
    Mitsuda, K
    Fujimoto, R
    Iyomoto, N
    Oshima, T
    Yamazaki, M
    Futamoto, K
    Audley, D
    Shoji, S
    Kudo, H
    Yokoyama, Y
    NEW CENTURY OF X-RAY ASTRONOMY, 2001, 251 : 548 - 549
  • [6] TES microcalorimeter development for future Italian X-ray astronomy missions
    Gatti, F
    Piro, L
    Pergolesi, D
    Colasanti, L
    Gastaldo, L
    Gomes, MR
    Repetto, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 559 (02): : 605 - 607
  • [7] TES microcalorimeter development for future Japanese X-ray astronomy missions
    Fujimoto, R
    Mitsuda, K
    Yamasaki, NY
    Iyomoto, N
    Oshima, T
    Takei, Y
    Futamoto, K
    Ichitsubo, T
    Fujimori, T
    Yoshida, K
    Ishisaki, Y
    Morita, U
    Koga, T
    Shinozaki, K
    Sato, K
    Takai, N
    Ohashi, T
    Kudo, H
    Sato, H
    Arakawa, T
    Kobayashi, H
    Izumi, T
    Ohtsuka, S
    Mori, K
    Shoji, S
    Osaka, T
    Homma, T
    Kuroda, Y
    Onishi, M
    Goto, M
    Beppu, F
    Tanaka, T
    Morooka, T
    Nakayama, S
    Chinone, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 431 - 434
  • [8] Multilayer x-ray optics for future missions
    Yamashita, K
    Kunieda, H
    Tawara, Y
    Tamura, K
    HOT UNIVERSE, 1998, (188): : 337 - 338
  • [9] Development of Superconducting Multilayer Wiring for a 400-Pixel TES X-ray Microcalorimeter Array
    Ezoe, Yuichiro
    Oishi, Shihoko
    Yamada, Shinya
    Enokijima, Yosuke
    Iijima, Noriko
    Toba, Reina
    Ishisaki, Yoshitaka
    Ohashi, Takaya
    Mitsuda, Kazuhisa
    Morooka, Toshimitsu
    Tanaka, Keiichi
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [10] Correcting Gain Drift in TES Detectors for Future X-Ray Satellite Missions
    Smith, Stephen J.
    Witthoeft, Michael C.
    Adams, Joseph S.
    Bandler, Simon R.
    Beaumont, Sophie
    Chervenak, James A.
    Cumbee, Renata S.
    Eckart, Megan E.
    Finkbeiner, Fred M.
    Hull, Sam V.
    Kelley, Richard L.
    Kilbourne, Caroline A.
    Leutenegger, Maurice A.
    Porter, Frederick S.
    Sakai, Kazuhiro
    Wakeham, Nicholas A.
    Wassell, Edward J.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2023, 33 (05)