We present a method to induce electric fields and drive electrotaxis (galvanotaxis) without the need for electrodes to be in contact with the media containing the cell cultures. We report experimental results using a modification of the transmembrane assay, demonstrating the hindrance of migration of breast cancer cells (SCP2) when an induced a.c. electric field is present in the appropriate direction (i.e. in the direction of migration). Of significance is that migration of these cells is hindered at electric field strengths many orders of magnitude (5 to 6) below those previously reported for d.c. electrotaxis and even in the presence of a chemokine (SDF-1α) or a growth factor (EGF). Induced a.c. electric fields applied in the direction of migration are also shown to hinder motility of non-transformed human mammary epithelial cells (MCF10A) in the presence of the growth factor EGF. In addition, we also show how our method can be applied to other cell migration assays (scratch assay) and by changing the coil design and holder, that it is also compatible with commercially available multi-well culture plates.
引用
收藏
相关论文
共 50 条
  • [1] Non-contact method for directing electrotaxis
    Ahirwar, Dinesh K.
    Nasser, Mohd W.
    Jones, Travis H.
    Sequin, Emily K.
    West, Joseph D.
    Henthorne, Timothy L.
    Javor, Joshua
    Kaushik, Aniruddha M.
    Ganju, Ramesh K.
    Subramaniam, Vish V.
    SCIENTIFIC REPORTS, 2015, 5
  • [2] Non-contact method for analysis of cavitating flows
    Bilus, Ignacijo
    Bizjan, Benjamin
    Lesnik, Luka
    Sirok, Brane
    Pecnik, Bostjan
    Dular, Matevz
    ULTRASONICS, 2017, 81 : 178 - 186
  • [3] The calibration method for non-contact electrostatic voltmeter
    Wei, Guang-Hui
    Pan, Xiao-Dong
    Liu, Cun-Li
    Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology, 2009, 29 (SUPPL. 2): : 80 - 82
  • [4] Study of a non-contact position measuring method
    Wang, Zhi-Qian
    Xie, Mu-Jun
    Qiao, Yan-Feng
    Guangxue Jishu/Optical Technique, 2003, 29 (04): : 431 - 433
  • [5] Photoelectric method for non-contact characterization of SiGe
    Tsidilkovski, Edward
    Steeples, Kenneth
    THIN SOLID FILMS, 2008, 517 (01) : 170 - 171
  • [6] Non-contact multiband method for emissivity measurement
    Mazikowski, A
    Chrzanowski, K
    INFRARED PHYSICS & TECHNOLOGY, 2003, 44 (02) : 91 - 99
  • [7] METHOD FOR NON-CONTACT THICKNESS AND CONDUCTIVITY GAGING
    BALL, E
    MATERIALS EVALUATION, 1975, 33 (09) : A54 - &
  • [8] New method for non-contact material testing
    Adhaesion Kleben und Dichten, 2019, 63 (09): : 38 - 41
  • [9] An optoelectronic non-contact inspecting method of taper
    Zhang, GY
    An, ZY
    Jiang, HL
    Li, CZ
    Gao, YJ
    Chen, RW
    AUTOMATED OPTICAL INSPECTION FOR INDUSTRY: THEORY, TECHNOLOGY, AND APPLICATIONS II, 1998, 3558 : 239 - 243
  • [10] Non-contact method for characterization of a rotational table
    Shattuck, Judson La Moure, III
    Parisi, Vincent M., II
    Smerdon, Arryn J.
    HEAD- AND HELMET-MOUNTED DISPLAYS XII: DESIGN AND APPLICATIONS, 2007, 6557