摘要
Spectrophotometric multicomponent analysis is considerd on the basis of inverse multivariate calibration with linear methods (ordinary least squares, principal component, ridge and partial least squares regression) and with the non-linear methods ACE and the non-linear partial least squares. The performance of the different methods is compared by paired F-tests. As an estimate of the error variance the residual mean sum of squares in the analysis of variance table is used. The comparison is demonstrated for the infrared spectrometric analysis of the hydroxyl group content of brown coal measured in diffuse reflectance. Although the error variances among the calibration methods differ gradually, the differences are much less pronounced at statistical level.
引用
收藏
页码:123 / 125
页数:2
相关论文
共 50 条
  • [1] Statistical comparison of calibration methods in multicomponent analysis
    Otto, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (02): : 123 - 125
  • [2] Comparison of multivariate calibration methods for quantitative analysis of multicomponent mixture of air toxic organic compounds by FTIR
    Gu, Binghe
    Wang, Junde
    Zhou, Xuetie
    Wu, Xuan
    Liu, Fang
    Li, Yan
    Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, 1998, 33 (07): : 1419 - 1436
  • [3] Comparison of multivariate calibration methods for quantitative analysis of multicomponent mixture of air toxic organic compounds by FTIR
    Gu, BH
    Wang, J
    Zhou, XT
    Wu, X
    Liu, F
    Li, Y
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 1998, 33 (07): : 1419 - 1436
  • [4] COMPARISON OF LINEAR STATISTICAL-METHODS FOR CALIBRATION OF NIR INSTRUMENTS
    NAES, T
    IRGENS, C
    MARTENS, H
    APPLIED STATISTICS-JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES C, 1986, 35 (02): : 195 - 206
  • [5] METHODS OF STATISTICAL ANALYSIS FOR THE PROFICIENCY TESTING DATA IN CALIBRATION
    Kachur, Sviatlana
    Efremova, Nadzeya
    PROCEEDINGS OF THE 3RD INTERNATIONAL PROFICIENCY TESTING CONFERENCE, PTCONF 2011, 2011, : 64 - 71
  • [6] COMPARISON OF METHODS OF STATISTICAL ANALYSIS OF ELECTROCARDIOSIGNALS
    AKHUTIN, VM
    BOGDANOV.EM
    SHKAPIN, BF
    SHTEIN, LB
    BIOPHYSICS-USSR, 1968, 13 (04): : 834 - &
  • [7] Comparison of certain methods of analysis of multicomponent nonstationary signals
    Slesarev, DA
    Gaev, GP
    MEASUREMENT TECHNIQUES, 1996, 39 (10) : 1052 - 1056
  • [8] A study on the applicability on multicomponent calibration methods in chemometrics
    Liu, SQ
    Wang, WW
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 45 (1-2) : 131 - 145
  • [9] A comparison of statistical methods for pharmacoeconomic analysis.
    Mayo, K
    Fong, D
    Forrest, A
    Paladino, J
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 1998, 63 (02) : 196 - 196
  • [10] A comparison of statistical methods for meta-analysis
    Brockwell, SE
    Gordon, IR
    STATISTICS IN MEDICINE, 2001, 20 (06) : 825 - 840