Effect of biomimetic conditions on mechanical and structural integrity of PGA/P4HB and electrospun PCL scaffolds

被引:0
作者
Leda Klouda
Claudia M. Vaz
Anita Mol
Frank P. T. Baaijens
Carlijn V. C. Bouten
机构
[1] Eindhoven University of Technology,Division of Biomechanics and Tissue Engineering, Department of Biomedical Engineering
[2] Rice University,Department of Bioengineering
来源
Journal of Materials Science: Materials in Medicine | 2008年 / 19卷
关键词
Ultimate Tensile Strength; Permanent Deformation; Average Fiber Diameter; Tissue Engineer Construct; Scaffold Type;
D O I
暂无
中图分类号
学科分类号
摘要
The selection of an appropriate scaffold represents one major key to success in tissue engineering. In cardiovascular applications, where a load-bearing structure is required, scaffolds need to demonstrate sufficient mechanical properties and importantly, reliable retention of these properties during the developmental phase of the tissue engineered construct. The effect of in vitro culture conditions, time and mechanical loading on the retention of mechanical properties of two scaffold types was investigated. First candidate tested was a poly-glycolic acid non-woven fiber mesh, coated with poly-4-hydroxybutyrate (PGA/P4HB), the standard scaffold used successfully in cardiovascular tissue engineering applications. As an alternative, an electrospun poly-ε-caprolactone (PCL) scaffold was used. A 15-day dynamic loading protocol was applied to the scaffolds. Additionally, control scaffolds were incubated statically. All studies were performed in a simulated physiological environment (phosphate-buffered saline solution, T = 37 °C). PGA/P4HB scaffolds showed a dramatic decrease in mechanical properties as a function of incubation time and straining. Mechanical loading had a significant effect on PCL scaffold properties. Degradation as well as fiber fatigue caused by loading promote loss of mechanical properties in PGA/P4HB scaffolds. For PCL, fiber reorganization due to straining seems to be the main reason behind the brittle behavior that was pronounced in these scaffolds. It is suggested that those changes in scaffolds’ mechanical properties must be considered at the application of in vitro tissue engineering protocols and should ideally be taken over by tissue formation to maintain mechanically stable tissue constructs.
引用
收藏
页码:1137 / 1144
页数:7
相关论文
共 125 条
  • [1] HOERSTRUP S. P.(2000)undefined Tissue Eng 6 75-undefined
  • [2] SODIAN R.(2002)undefined J. Biomed. Mater. Res 58 401-undefined
  • [3] SPERLING J. S.(2003)undefined Thorac. Cardiovasc. Surg 51 78-undefined
  • [4] VACANTI J. P.(2003)undefined Biomater 24 2523-undefined
  • [5] MAYER J. E.(2000)undefined Biomater 21 2529-undefined
  • [6] SODIAN R.(2002)undefined Biomacromol 3 232-undefined
  • [7] LEMKE T.(2003)undefined Polymer 44 4959-undefined
  • [8] LOEBE M.(2002)undefined J. Biomed. Mater. Res 60 613-undefined
  • [9] HOERSTRUP S. P.(2003)undefined J. Control. Rel. 89 341-undefined
  • [10] POTAPOV E. V.(2004)undefined J. Biomed. Mater. Res. 70A 603-undefined