A boronate gel-based synthetic platform for closed-loop insulin delivery systems

被引:0
作者
Akira Matsumoto
Siyuan Chen
机构
[1] Tokyo Medical and Dental University,Institute of Biomaterials and Bioengineering
[2] Kanagawa Institute of Industrial Science and Technology,Research Institute for Biomaterials, Tech Institute for Advanced Materials, College of Materials Science and Engineering, Suqian Advanced Materials Industry Technology Innovation Center, NJTech
[3] Nanjing Tech University,BARTY Joint Research Center for Innovative Medical Technology
来源
Polymer Journal | 2021年 / 53卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Diabetes is one of the most devastating global diseases with an ever-increasing number of patients. Achieving persistent glycemic control in a painless and convenient way is an unmet goal for diabetes management. Insulin therapy is commonly utilized for diabetes treatment and usually relies on patient self-injection. This not only impairs a patient’s quality of life and fails to precisely control the blood glucose level but also brings the risk of life-threatening hypoglycemia. “closed-loop” insulin delivery systems could avoid these issues by providing on-demand insulin delivery. However, safety concerns limit the application of currently developed electronics-derived or enzyme-based systems. Phenylboronic acid (PBA), with the ability to reversibly bind glucose and a chemically tailored binding specificity, has attracted substantial attention in recent years. This focus review provides an overview of PBA-based versatile insulin delivery platforms developed in our group, including new PBA derivatives, glucose-responsive gels, and gel-combined medical devices, with a unique “skin layer” controlled diffusion feature.
引用
收藏
页码:1305 / 1314
页数:9
相关论文
共 50 条
  • [31] Correction to: New closed-loop insulin systems
    Charlotte K. Boughton
    Roman Hovorka
    Diabetologia, 2021, 64 (6) : 1455 - 1455
  • [32] Enlarging the loop: closed-loop insulin delivery for type 1 diabetes
    Galderisi, Alfonso
    Sherr, Jennifer L.
    LANCET, 2018, 392 (10155) : 1282 - 1284
  • [33] Closed-loop subcutaneous insulin delivery based on subcutaneous glucose sensing in adults
    Rebrin, K
    Steil, GM
    Panteleon, AE
    Hariri, F
    Darwin, C
    Saad, MF
    DIABETOLOGIA, 2004, 47 : A93 - A93
  • [34] A translational platform for prototyping closed-loop neuromodulation systems
    Afshar, Pedram
    Khambhati, Ankit
    Stanslaski, Scott
    Carlson, David
    Jensen, Randy
    Linde, Dave
    Dani, Siddharth
    Lazarewicz, Maciej
    Cong, Peng
    Giftakis, Jon
    Stypulkowski, Paul
    Denison, Tim
    FRONTIERS IN NEURAL CIRCUITS, 2013, 6
  • [35] Closed-Loop Control Systems in a Platform for Fouling Detection
    Melo, T. R.
    Silva, J. J.
    Rocha Neto, J. S.
    2014 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) PROCEEDINGS, 2014, : 392 - 396
  • [36] TIME-DELAY COMPENSATION FOR CLOSED-LOOP INSULIN DELIVERY SYSTEMS - A SIMULATION STUDY
    REBOLDI, GP
    HOME, PD
    CALABRESE, G
    FABIETTI, PG
    BRUNETTI, P
    BENEDETTI, MM
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (06) : 350 - 358
  • [37] Clinical experience with an implanted closed-loop insulin delivery system
    Renard, Eric
    ARQUIVOS BRASILEIROS DE ENDOCRINOLOGIA E METABOLOGIA, 2008, 52 (02) : 349 - 354
  • [38] Closed-loop insulin delivery: from bench to clinical practice
    Roman Hovorka
    Nature Reviews Endocrinology, 2011, 7 : 385 - 395
  • [39] BIOMATERIALS FOR IMPLANTED CLOSED-LOOP INSULIN DELIVERY SYSTEM - A REVIEW
    WILKINS, E
    RADFORD, W
    BIOSENSORS & BIOELECTRONICS, 1990, 5 (03) : 167 - 213
  • [40] Closed-Loop Insulin Delivery for Outpatients With Type 2 Diabetes
    Slomski, Anita
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 326 (12): : 1139 - 1139