High-throughput determination of barbiturates in human plasma using on-line column-switching ultra-fast liquid chromatography–tandem mass spectrometry

被引:0
作者
Xiao-Pen Lee
Takeshi Kumazawa
Chika Hasegawa
Tetsuya Arinobu
Hiroshi Seno
Osamu Suzuki
Keizo Sato
机构
[1] Showa University School of Medicine,Department of Legal Medicine
[2] Toho University School of Medicine,Department of Legal Medicine
[3] Aichi Medical University School of Medicine,Department of Chemistry
[4] Aichi Medical University School of Medicine,Department of Legal Medicine
[5] Hamamatsu University School of Medicine,Department of Legal Medicine
来源
Forensic Toxicology | 2013年 / 31卷
关键词
Barbiturate drugs; Monolithic column; On-line column switching; UFLC–MS–MS; Human plasma; Phenobarbital;
D O I
暂无
中图分类号
学科分类号
摘要
A high-throughput method was developed for determinations of eight barbiturates (barbital, allobarbital, phenobarbital, cyclobarbital, amobarbital, secobarbital, thiopental, and thiamylal) in human plasma by on-line column-switching ultra-fast liquid chromatography–tandem mass spectrometry (MS–MS). Plasma samples (100 μl) spiked with the eight barbiturates and 5-(4-methylphenyl)-5-phenylhydantoin (internal standard) were diluted with 300 μl of 13.3 mM ammonium acetate/acetonitrile (33:67, v/v). After centrifugation and filtration, the clear supernatant was injected directly onto the extraction column (Oasis HLB cartridge column). The following procedure was fully automated. The analytes retained on the extraction column were eluted by backflushing of the extraction column and introduced onto the analytical column (Phenomenex Onyx monolithic C18 column, 100 mm × 4.6 mm i.d.) by column switching. Quantification was performed by multiple reaction monitoring with negative-ion atmospheric pressure chemical ionization. Good peak separation and peak shapes of the eight drugs were achieved within an analysis time of 3 min, including the extraction time. All drugs spiked into plasma showed recoveries of 80–93 %. The regression equations for the eight drugs showed excellent linearities in the range of 10–5000 ng/ml of plasma, and the limits of detection ranged from 1.0 to 10 ng/ml. The lower and upper limits of quantitation were 10–50 ng/ml and 5000 ng/ml, respectively. Intraday and interday coefficients of variation for all the drugs were not >9.1 %. The accuracies of quantitation were 92.0–108 %. The method was successfully applied to determination of the level of amobarbital in human plasma after its oral administration to a volunteer.
引用
收藏
页码:9 / 20
页数:11
相关论文
共 135 条
  • [31] Lores M(undefined)undefined undefined undefined undefined-undefined
  • [32] Cela R(undefined)undefined undefined undefined undefined-undefined
  • [33] Yoshida M(undefined)undefined undefined undefined undefined-undefined
  • [34] Akane A(undefined)undefined undefined undefined undefined-undefined
  • [35] Nishikawa M(undefined)undefined undefined undefined undefined-undefined
  • [36] Watabiki T(undefined)undefined undefined undefined undefined-undefined
  • [37] Tsuchihashi H(undefined)undefined undefined undefined undefined-undefined
  • [38] Ye FQ(undefined)undefined undefined undefined undefined-undefined
  • [39] Pan JC(undefined)undefined undefined undefined undefined-undefined
  • [40] Hu GX(undefined)undefined undefined undefined undefined-undefined