Prevalence, Patterns and Variations of Anterior Loop of Inferior Alveolar Nerve—A CBCT Based Retrospective Study

被引:0
作者
Suvranita Jena
Rajat Panigrahi
Abhishek Ranjan Pati
Shamimul Hasan
机构
[1] Siksha ‘O’ Anusandhan University,Department of Oral Medicine and Radiology, Institute of Dental Sciences
[2] Faculty of Dentistry,Department of Oral Medicine and Radiology
来源
Indian Journal of Otolaryngology and Head & Neck Surgery | 2022年 / 74卷
关键词
Anterior Loop; Cone Beam Computed Tomography; Inferior alveolar nerve; Mental Foramen;
D O I
暂无
中图分类号
学科分类号
摘要
The fragment of inferior alveolar nerve (IAN) existing anterior to the mental foramen (MF), before dividing the canal, is known as the “Anterior Loop of the IAN”. The presence of anterior loop (AL) is important when placing the implant in inter foraminal area of the mandible or during any other surgical procedure. It is imperative to precisely determine the position and dimensions of these anatomical variations on a cone-beam CT (CBCT) scan. To estimate the prevalence and pattern of anterior loop of IAN and establish any corelation between dimension of the MF with length and angulation of the AL of the IAN. Total 178 CBCT samples were collected fulfilling the inclusion criteria from a private diagnostic centre in Bhubaneswar, Odisha. The greatest diameter of the mental foramen was measured along with anterior loop length and angulation in the panoramic section of the CBCT scan. The angulation formed and the length was corelated with the greatest diameter of the mental foramen and analysed. Our study reveals that the AL was more frequently seen among males, predominantly on the left side of the mandible. The relationship between length of the anterior loop and diameter of the mental foramen demonstrated a mild negative corelation. There was no possible corelation present between angle formed by anterior loop with inferior alveolar canal and diameter of mental foramen. A small positive corelation was established between length of anterior loop and angle formed by the anterior loop with inferior alveolar canal. CBCT scans should be recommended for pre-surgical evaluation of anatomical variations in the mandibular region. Also, a safe margin of 3–4 mm anterior to mental foramen should be maintained while working in the premolar area.
引用
收藏
页码:5424 / 5431
页数:7
相关论文
共 191 条
  • [1] Arai Y(1999)Development of a compact computed tomographic apparatus for dental use Dento Maxillo Facial Radiol 28 245-248
  • [2] Tammisalo E(2017)Assessment of the anterior loop of the inferior alveolar nerve via cone-beam computed tomography J Korean Assoc Oral Maxillofac Surg 43 395-400
  • [3] Iwai K(2010)Evaluation of the visibility and the course of the mandibular incisive canal and the lingual foramen using cone-beam computed tomography Clin Oral Implants Res 21 766-771
  • [4] Hashimoto K(2008)Retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and spiral computerized tomography Int J Oral Maxillofac Implants 23 919-925
  • [5] Shinoda K(1993)An anatomical study of mental neurovascular bundle - implant relationship Int J Oral Maxillofac Implants 8 563-567
  • [6] Shaban B(1994)A classification of the intraosseous paths of the mental nerve Int J Oral Maxillofac Implant 9 339-344
  • [7] Khajavi A(2019)Radiological study on the anterior loop of inferior alveolar nerve Indian J Public Health Res Develop 10 595-599
  • [8] Khaki N(2012)The anterior loop of the inferior alveolar nerve: Prevalence, measurement of its length and a recommendation for interforaminal implant installation based on cone beam CT imaging Clin Oral Implants Res 23 1022-1030
  • [9] Mohiti Y(2006)The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review J Periodontol 77 1933-1943
  • [10] Mehri T(2003)Presence and course of the incisive canal in the human mandibular interforaminal region: two-dimensional imaging versus anatomical observations Surg Radiol Anat 25 416-423