Depth-Resolved Full-Field Measurement of Corneal Deformation by Optical Coherence Tomography and Digital Volume Correlation

被引:0
|
作者
J. Fu
M. Haghighi-Abayneh
F. Pierron
P. D. Ruiz
机构
[1] Loughborough University,Wolfson School of Mechanical and Manufacturing Engineering
[2] University of Southampton,Faculty of Engineering and the Environment
来源
Experimental Mechanics | 2016年 / 56卷
关键词
Cornea; Optical coherence tomography; Refraction correction; Digital volume correlation; 3D full-field deformation measurement; Inflation test;
D O I
暂无
中图分类号
学科分类号
摘要
The study of vertebrate eye cornea is an interdisciplinary subject and the research on its mechanical properties has significant importance in ophthalmology. The measurement of depth-resolved 3D full-field deformation behaviour of cornea under changing intraocular pressure is a useful method to study the local corneal mechanical properties. In this work, optical coherence tomography was adopted to reconstruct the internal structure of a porcine cornea inflated from 15 to 18.75 mmHg (close to the physical porcine intraocular pressure) in the form of 3D image sequences. An effective method has been developed to correct the commonly seen refraction induced distortions in the optical coherence tomography reconstructions, based on Fermat’s principle. The 3D deformation field was then determined by performing digital volume correlation on these corrected 3D reconstructions. A simple finite element model of the inflation test was developed and the predicted values were compared against digital volume correlation results, showing good overall agreement.
引用
收藏
页码:1203 / 1217
页数:14
相关论文
共 50 条
  • [41] Full-field Optical Coherence Tomography Apply in Sphere Measurements
    Shi Wei
    Li Weiwei
    Li Juncheng
    Wang Jingyu
    Wang Jianguo
    ADVANCED OPTICAL DESIGN AND MANUFACTURING TECHNOLOGY AND ASTRONOMICAL TELESCOPES AND INSTRUMENTATION, 2016, 10154
  • [42] Full-field optical coherence tomography based on CCD detector
    Xu, Zhong-Bao
    Zhang, Nan
    Yi, Jun
    Guangdian Gongcheng/Opto-Electronic Engineering, 2007, 34 (01): : 37 - 40
  • [43] Fibre imaging bundles for full-field optical coherence tomography
    Ford, H. D.
    Tatam, R. P.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (09) : 2949 - 2957
  • [44] Motion artifact suppression in full-field optical coherence tomography
    Sacchet, Delphine
    Brzezinski, Michal
    Moreau, Julien
    Georges, Patrick
    Dubois, Arnaud
    APPLIED OPTICS, 2010, 49 (09) : 1480 - 1488
  • [45] Methods and applications of full-field optical coherence tomography: a review
    Wang, Ling
    Fu, Rongzhen
    Xu, Chen
    Xu, Mingen
    JOURNAL OF BIOMEDICAL OPTICS, 2022, 27 (05)
  • [46] Depth-resolved stress field measurement of multilayered system using swept-source polarization-sensitive optical coherence tomography
    Zhang, Xinya
    Chen, Jinlong
    Sun, Cuiru
    OPTICS AND LASERS IN ENGINEERING, 2024, 178
  • [47] Bond-selective full-field optical coherence tomography
    Zong, Haonan
    Yurdakul, Celalettin
    Zhao, Jian
    Wnag, Zian
    Chen, Fukai
    Unlu, M. Selim
    Cheng, Ji-xin
    OPTICS EXPRESS, 2023, 31 (25) : 41202 - 41218
  • [48] Experimental demonstration of full-field quantum optical coherence tomography
    ZEFERINO IBARRABORJA
    CARLOS SEVILLAGUTIRREZ
    ROBERTO RAMREZALARCN
    HECTOR CRUZRAMREZ
    ALFRED BUREN
    Photonics Research, 2020, 8 (01) : 51 - 56
  • [49] Multiple Delay Lines Full-field Optical Coherence Tomography
    Wang, Jingyu
    Dainty, Christopher
    Podoleanu, Adrian
    1ST CANTERBURY WORKSHOP ON OPTICAL COHERENCE TOMOGRAPHY AND ADAPTIVE OPTICS, 2008, 7139
  • [50] Thermal-light full-field optical coherence tomography
    Vabre, L
    Dubois, A
    Boccara, AC
    OPTICS LETTERS, 2002, 27 (07) : 530 - 532