Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry

被引:0
作者
Susan S.-C. Tai
Bei Xu
Michael J. Welch
Karen W. Phinney
机构
[1] National Institute of Standards and Technology,Analytical Chemistry Division
[2] National Institute of Metrology,undefined
来源
Analytical and Bioanalytical Chemistry | 2007年 / 388卷
关键词
Testosterone; Reference measurement procedure; Electrospray ionization; Isotope dilution; Liquid chromatography/tandem mass spectrometry; LC/MS/MS; Solid-phase extraction; Liquid–liquid extraction;
D O I
暂无
中图分类号
学科分类号
摘要
A candidate reference measurement procedure for total testosterone in human serum involving isotope dilution (ID) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. The endogenous testosterone and its internal standard (testosterone-d3) were extracted from the serum matrix using a combination of solid-phase extraction and liquid–liquid extraction prior to reversed-phase LC/MS/MS. Accuracy of the measurements was evaluated by a recovery study using testosterone-spiked serum. The recovery of the added testosterone ranged from 100.0 to 100.3%. This method was applied to the determination of testosterone in frozen serum samples from three individual donors (one female and two males) with the testosterone concentrations ranging from 0.3 to 8.5 ng g−1. Repeatability with within-set coefficients of variation (CVs) from 0.1 to 1.0% and intermediate precision with between-set CVs from 0.1 to 0.5% for both female and male serum materials were demonstrated. Excellent linearity was obtained for all linear regression lines. The detection limit at a signal-to-noise ratio of approximately 3 was 2 pg of testosterone in serum. Structural analogs as well as testosterone metabolites were tested and found to not interfere with the measurement of testosterone. This well-characterized LC/MS/MS method for serum testosterone, which demonstrates good accuracy and precision, and low susceptibility to interferences, qualifies as a reference measurement procedure that can be used to provide an accuracy base to which routine methods for testosterone can be compared and that will serve as a standard of higher order for measurement traceability.
引用
收藏
页码:1087 / 1094
页数:7
相关论文
共 76 条
[1]  
Bhasin S(1998)undefined J Clin Endocrinol Metab 83 3435-3448
[2]  
Bagatell CJ(2005)undefined Aging Male 8 194-202
[3]  
Bremner WJ(2007)undefined J Clin Endocrinol Metab 92 405-413
[4]  
Plymate SR(2004)undefined J Clin Endocrinol Metab 89 534-543
[5]  
Tenover JL(2003)undefined Clin Chem 49 1381-1395
[6]  
Korenman SG(1996)undefined Eur J Clin Chem Clin Biochem 34 853-860
[7]  
Nieschlag E(1994)undefined Anal Chem 66 4116-4119
[8]  
Goncharov N(1979)undefined J Steroid Biochem 11 117-123
[9]  
Katsya G(2004)undefined Anal Chem 76 5092-5096
[10]  
Dobracheva A(1999)undefined Rapid Commun Mass Spectrom 13 1924-1931