5 year follow up of a hydroxyapatite coated short stem femoral component for hip arthroplasty: a prospective multicentre study

被引:0
|
作者
Monil Karia
Kartik Logishetty
Hardeep Johal
Thomas C. Edwards
Justin P. Cobb
机构
[1] Imperial College London,MSk Lab
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Short stem, uncemented femoral implants for hip arthroplasty are bone conserving achieving stability through initial metaphyseal press-fit and biological fixation. This study aimed to evaluate the survivorship, mid-term function and health related quality of life outcomes in patients who have undergone total hip arthroplasty (THA) with a fully hydroxyapatite coated straight short stem femoral component with up to 5 years follow-up. 668 patients were recruited to a multicentre study investigating the performance of the cementless Furlong Evolution® stem for THA. 137 patients withdrew at various time points. The mean follow-up was 49 months. Clinical (Harris Hip Score (HHS), radiographic and patient-reported outcome measures—Oxford Hip Score (OHS) and EuroQol 5D (EQ-5D), were recorded pre-operatively and at 6 weeks, 6 months, 1 year, 3 year and 5 year follow ups. At 5-year follow-up, 12 patients underwent revision surgery, representing a cumulative revision rate of 1.8%. Median OHS, HHS and EQ5D scores improved significantly: OHS improved from a pre-operative median of 21 (IQR 14–26) to 47 (IQR 44–48) (p < 0.001). HHS improved from 52 (IQR 40–63) to 98 (IQR 92–100) (p < 0.001) and EQ5D improved from 70 (IQR 50–80) to 85 (IQR 75–95) (p < 0.001). This fully HA-coated straight short femoral stem implant demonstrated acceptable mid-term survivorship and delivered substantial improvements in function and quality of life after THA.
引用
收藏
相关论文
共 50 条
  • [1] 5 year follow up of a hydroxyapatite coated short stem femoral component for hip arthroplasty: a prospective multicentre study
    Karia, Monil
    Logishetty, Kartik
    Johal, Hardeep
    Edwards, Thomas C.
    Cobb, Justin P.
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [2] Results of a Hydroxyapatite-Coated Modular Femoral Stem in Primary Total Hip Arthroplasty. A Minimum 5-Year Follow-Up
    Garcia-Rey, Eduardo
    Munoz, Teresa
    Montejo, Jorge
    Martinez, Javier
    JOURNAL OF ARTHROPLASTY, 2008, 23 (08): : 1132 - 1139
  • [3] Prospective five-year subsidence analysis of a cementless fully hydroxyapatite-coated femoral hip arthroplasty component
    Clauss, Martin
    Van der Straeten, Catherine
    Goossens, Marc
    HIP INTERNATIONAL, 2014, 24 (01) : 91 - 97
  • [4] Long-term follow-up of an uncemented proximally hydroxyapatite-coated femoral stem in total hip arthroplasty
    Yee, A. H. F.
    Chan, V. W. K.
    Fu, H.
    Chan, P-K
    Chiu, K. Y.
    BONE & JOINT JOURNAL, 2024, 106B (03): : 110 - 114
  • [5] A Randomized Trial of Hydroxyapatite-Coated Femoral Stems in Total Hip Arthroplasty A 13-Year Follow-Up
    Camazzola, Dan
    Hammond, Terry
    Gandhi, Rajiv
    Davey, J. Roderick
    JOURNAL OF ARTHROPLASTY, 2009, 24 (01): : 33 - 37
  • [6] Total Hip Arthroplasty with a Collarless, Tapered, Fiber Metal Proximally Coated Femoral Stem Minimum 5-Year Follow-Up
    Klein, Gregg R.
    Levine, Harlan B.
    Nafash, Susan C.
    Lamothe, Helena C.
    Hartzband, Mark A.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (04): : 579 - 585
  • [7] Outcome of short versus conventional stem for total hip arthroplasty in the femur with a high cortical index: a five year follow-up prospective multicentre comparative study
    Pogliacomi, Francesco
    Schiavi, Paolo
    Grappiolo, Guido
    Ceccarelli, Francesco
    Vaienti, Enrico
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (01) : 61 - 68
  • [8] Outcome of short versus conventional stem for total hip arthroplasty in the femur with a high cortical index: a five year follow-up prospective multicentre comparative study
    Francesco Pogliacomi
    Paolo Schiavi
    Guido Grappiolo
    Francesco Ceccarelli
    Enrico Vaienti
    International Orthopaedics, 2020, 44 : 61 - 68
  • [9] Sixteen-year follow-up of the cemented spectron femoral stem for hip arthroplasty
    Issack, PS
    Botero, HG
    Hiebert, RN
    Bong, MR
    Stuchin, SA
    Zuckerman, JD
    Di Cesare, PE
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07): : 925 - 930
  • [10] Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component
    Raman, R
    Kamath, RP
    Parikh, A
    Angus, PD
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (08): : 1061 - 1067