Numerical simulation on the seismic performance of retrofitted masonry walls based on the combined finite-discrete element method

被引:0
作者
Biye Wu
Junwu Dai
Huan Jin
Wen Bai
Bowen Chen
机构
[1] China Earthquake Administration,Key Laboratory of Earthquake Engineering and Engineering Vibration, Institute of Engineering Mechanics
[2] Ministry of Emergency Management,Key Laboratory of Earthquake Disaster Mitigation
[3] Guangdong University of Petrochemical Technology,undefined
来源
Earthquake Engineering and Engineering Vibration | 2023年 / 22卷
关键词
masonry wall; external steel-meshed mortar layer; combined finite-discrete element method; hysteretic curve; ultimate bearing capacity;
D O I
暂无
中图分类号
学科分类号
摘要
Due to the long construction life, improper design methods, brittle material properties and poor construction techniques, most existing masonry structures do not perform well during earthquakes. The retrofitting method using an external steel-meshed mortar layer is widely used to retrofit existing masonry buildings. Assessing the seismic performance of masonry walls reinforced by an external steel-meshed mortar layer reasonably and effectively is a difficult subject in the research field of masonry structures. Based on the combined finite-discrete elements method, the numerical models of retrofitted brick walls with four different masonry mortar strengths by an external mortar layer are established. The shear strength of mortar and the contact between the retrofitted mortar layer and the brick blocks are discussed in detail. The failure patterns and load-displacement curves of the retrofitted brick walls were obtained by applying low cycle reciprocating loads to the numerical model, and the bearing capacity and the failure mechanism of the retrofitted walls were obtained by comparing the failure patterns, ultimate bearing capacity, deformability and other aspects with the tests. This study provides a basis for improving the seismic strengthening design method of masonry structures and helps to better assess the seismic performance of masonry structures after retrofitting.
引用
收藏
页码:777 / 805
页数:28
相关论文
共 87 条
[1]  
Addessi D(2014)Modeling Approaches for Masonry Structures Open Civ. Eng. J 8 288-300
[2]  
Marfia S(2011)Seismic Behavior of Unreinforced and Confined Brick Masonry Walls Before and After Ferrocement Overlay Retrofitting International Journal of Architectural Heritage 6 665-688
[3]  
Sacco E(2014)A DEM Based Tool for the Safety Analysis of Masonry Gravity Dams Engineering Structures 59 248-260
[4]  
Toti J(1971)A Computer Model for Simulating Progressive Large-Scale Movements in Blocky Rock Systems Proc.int.symp.on Rock Fracture 1 11-18
[5]  
Ashraf M(2015)Structural Performance of Confined Masonry Walls Retrofitted Using Ferrocement and GFRP Under In-Plane Cyclic Loading Engineering Structures 94 54-69
[6]  
Khan A N(2018)Experimental Study on Masonry Building Strengthened with Ferrocement Layers International Journal of GEOMATE 14 84-90
[7]  
Naseer A(2021)Seismic Collapse Simulation of Existing Masonry Buildings with Different Retrofitting Techniques Earthquake Engineering and Engineering Vibration 20 127-139
[8]  
Ali Q(1994)The Study on Adopting the Cover with Cement Mortar and the Cover with Reinforced Cement Mortar to Strengthen Brick Masonry Journal of Tianjin University 27 764-770
[9]  
Alam B(2015)Discrete Element Modelling of Stone Masonry Walls with Varying Core Conditions: Prince of Wales Fort Case Study International Journal of Architectural Heritage 9 564-580
[10]  
Bretas EM(2019)Observed Failure Modes of Unreinforced Masonry Buildings During the 2015 Hindu Kush earthquake Earthquake Engineering and Engineering Vibration 18 301-314