Investigation on liquid film of urea–water solutions with diode laser absorption spectroscopy

被引:2
|
作者
Huinan Yang
Xiaolong Guo
Wu Zhou
Benting Chen
Jiarui Hu
Mingxu Su
Xiaoshu Cai
机构
[1] University of Shanghai for Science and Technology,School of Energy and Power Engineering
[2] University of Shanghai for Science and Technology,Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering
来源
Experiments in Fluids | 2015年 / 56卷
关键词
Film Thickness; Mass Fraction; Liquid Film; Selective Catalytic Reduction; Liquid Film Thickness;
D O I
暂无
中图分类号
学科分类号
摘要
Measurement of multiparameter of liquid films (e.g., film thickness and concentration) is very important to understand the film formation processes in industrial applications. Here, a novel diode laser absorption spectroscopy (DLAS) sensor was developed to simultaneously measure the liquid film thickness and concentration of urea–water solutions by forming the transmittance ratio at two wavenumber positions. The performance of the sensor employed two diode lasers (6613.25 and 7187.50 cm−1) was first validated using a calibration tool providing liquid film of urea–water solutions with known film thickness (100–1000 μm) and mass fractions (5–50 wt%), and then, the sensor was applied to study a free-falling film of urea–water solutions on a vertical transparent quartz plate. Shadowgraph images were simultaneously taken as a means to obtain falling film thickness, and it was observed that measured film thickness was in good agreement with DLAS method and shadowgraph technique, and the deviation between these two techniques was 4.1 % when the falling film was stable.
引用
收藏
相关论文
共 50 条
  • [31] Study on Frequency Stabilization of Diode Laser Saturated Absorption Spectroscopy
    WangMingdong
    FengGaoping
    Hong Yanji
    WangDapeng
    INTERNATIONAL CONFERENCE ON OPTOELECTRONICS AND MICROELECTRONICS TECHNOLOGY AND APPLICATION, 2017, 10244
  • [32] Measurement of an ambient air leak by diode laser absorption spectroscopy
    Chernyshov, Alexander K.
    Mikheyev, Pavel A.
    ASIA-PACIFIC CONFERENCE ON FUNDAMENTAL PROBLEMS OF OPTO- AND MICROELECTRONICS, 2017, 10176
  • [33] DIODE-LASER ABSORPTION-SPECTROSCOPY FOR PROCESS DIAGNOSTICS
    BOMSE, DS
    HOVDE, DC
    OH, DB
    SILVER, JA
    STANTON, AC
    ANDERSON, HC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 143 - ANYL
  • [34] Diode laser absorption spectroscopy for studies of gas exchange in fruits
    Persson, L.
    Gao, H.
    Sjoholm, M.
    Svanberg, S.
    OPTICS AND LASERS IN ENGINEERING, 2006, 44 (07) : 687 - 698
  • [35] Use of tunable diode laser absorption spectroscopy for atmospheric measurements
    Schiff, H.I.
    Mackay, G.I.
    Bechara, J.
    Research on Chemical Intermediates, 1994, 20 (3-5)
  • [36] Application of Tunable Diode Laser Absorption Spectroscopy in Breath Diagnosis
    Sun Liqun
    Zou Mingli
    Wang Xuan
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2021, 48 (15):
  • [37] Piezo-locking a diode laser with saturated absorption spectroscopy
    Debs, J. E.
    Robins, N. P.
    Lance, A.
    Kruger, M. B.
    Close, J. D.
    APPLIED OPTICS, 2008, 47 (28) : 5163 - 5166
  • [38] Atmospheric Measurements of HONO by Tunable Diode Laser Absorption Spectroscopy
    C. L. Schiller
    S. Locquiao
    Timothy J. Johnson
    G.W. Harris
    Journal of Atmospheric Chemistry, 2001, 40 : 275 - 293
  • [39] Research Progress on the Application of Tunable Diode Laser Absorption Spectroscopy
    Nie Wei
    Kan Ruifeng
    Yang Chenguang
    Chen Bing
    Xu Zhenyu
    Liu Wenqing
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2018, 45 (09):
  • [40] Temperature measurements based on tunable diode laser absorption spectroscopy
    Xu Zhen-Yu
    Liu Wen-Qing
    Liu Jian-Guo
    He Jun-Feng
    Yao Lu
    Ruan Jun
    Chen Jiu-Ying
    Li Han
    Yuan Song
    Geng Hui
    Kan Rui-Feng
    ACTA PHYSICA SINICA, 2012, 61 (23)