Statistical Properties of the Dielectric Strength of Triggered Vacuum Switches

被引:0
|
作者
D. F. Alferov
V. A. Nevrovskii
V. A. Sidorov
机构
[1] All-Russia Lenin Electrotechnical Institute,
[2] MATI Tsiolkovskii Russian State Technological University,undefined
来源
Instruments and Experimental Techniques | 2004年 / 47卷
关键词
Physical Chemistry; Probability Distribution; Measuring Technique; Distribution Curve; Practical Importance;
D O I
暂无
中图分类号
学科分类号
摘要
The dielectric strength of triggered vacuum switches (TVSs) was studied using two measuring techniques. In the first of these, the voltage of the first TVS breakdown was measured at every slow increase in the voltage of the commercial frequency. In the second, a constant preset voltage was applied to a TVS several times until the gap was broken down. In this case, the number of successful experiments before TVS breakdown was recorded. It is shown that the results from processing the data obtained by different methods of measurement are in satisfactory agreement. The practical importance of the second measuring technique for determining the region corresponding to low breakdown probabilities in the TVS-breakdown probability distribution curve is demonstrated.
引用
收藏
页码:63 / 68
页数:5
相关论文
共 45 条
  • [1] Statistical properties of the dielectric strength of triggered vacuum switches
    Alferov, DF
    Nevrovskii, VA
    Sidorov, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2004, 47 (01) : 63 - 68
  • [2] Electric Breakdown Strength of High-Current Triggered Vacuum Switches
    V. A. Sidorov
    D. F. Alferov
    Instruments and Experimental Techniques, 2001, 44 : 72 - 80
  • [3] Electric breakdown strength of high-current triggered vacuum switches
    Sidorov, VA
    Alferov, DF
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2001, 44 (01) : 72 - 80
  • [4] Application of Triggered Vacuum Switches in a High-Voltage High-Speed Protective Device
    D. F. Alferov
    N. V. Matveev
    V. A. Sidorov
    D. A. Khabarov
    Instruments and Experimental Techniques, 2004, 47 : 360 - 367
  • [5] Optimum Breakdown Charge for Maximum Dielectric Strength in Spark Conditioning in Vacuum under a Non-uniform Electric Field
    Kojima, H.
    Takahashi, T.
    Hayakawa, N.
    Hasegawa, K.
    Sakaki, M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (04) : 2660 - 2665
  • [6] Statistical models of probability distribution of dielectric parameters of rocks
    Veksler, V.A.
    Bashirov, A.V.
    Fiziko-Tekhnicheskie Problemy Razrabotki Poleznykh Iskopaemykh, 1991, (01): : 70 - 75
  • [7] Transport Properties of the Interface Metal Chalcogenide/Vacuum
    Konev, V. N.
    Nadolsky, A. L.
    Krzhivitskaya, J. E.
    IONICS, 2001, 7 (1-2) : 138 - 141
  • [8] Transport properties of the interface metal chalcogenide/vacuum
    V. N. Konev
    A. L. Nadolsky
    J. E. Krzhivitskaya
    Ionics, 2001, 7 : 138 - 141
  • [9] Statistical properties of world investment networks
    Song, Dong-Ming
    Jiang, Zhi-Qiang
    Zhou, Wei-Xing
    PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2009, 388 (12) : 2450 - 2460
  • [10] Statistical Estimate of Uniaxial Compressive Strength of Rock Based on Shore Hardness
    Zavacky, Martin
    Stefanak, Jan
    Horak, Vladislav
    Mica, Lumir
    ISRM EUROPEAN ROCK MECHANICS SYMPOSIUM EUROCK 2017, 2017, 191 : 248 - 255