Harm Analysis of Spring Defects in Circuit Breaker Mechanical Failure

被引:0
|
作者
Liang Huang
Xinru Mao
Hong Guo
机构
[1] State Grid Chongqing Electric Power CO. Yongchuan Power Supply Branch Company,
来源
Journal of Failure Analysis and Prevention | 2020年 / 20卷
关键词
Power system; Spring defect; Circuit breaker;
D O I
暂无
中图分类号
学科分类号
摘要
With the continuous development of the power system, the importance of circuit breakers has gradually emerged, becoming a key link to ensure the normal operation of the power system. However, circuit breaker mechanical failure defects often occur in the power system, such as plum blossom contact defects, split closing coil defects, tentacle defects, etc., which inhibits the normal operation of the power system and also increases the operation and maintenance costs of power companies. Based on this, this paper takes the Taiyuan Power Grid as an example to study the harm of spring defects in circuit breaker machinery, aiming to find out an effective method to eliminate the spring defects in order to achieve the purpose of contributing to the normal operation of the power grid.
引用
收藏
页码:888 / 894
页数:6
相关论文
共 50 条
  • [31] Analysis of conditions in circuit breaker
    Hamler, A
    Bizjak, M
    Jesenik, M
    Stumberger, B
    Trlep, M
    ELECTROMAGNETIC FIELDS IN ELECTRICAL ENGINEERING, 2002, 22 : 196 - 201
  • [32] Modeling of Dynamic Characteristics for Spring Operating Gas Circuit Breaker
    Hashimoto, H.
    Okubo, K.
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [33] The Research and Optimum Design for Vacuum Circuit Breaker with Spring Mechanism
    Han, Shai-gen
    Huang, Qiang
    You, Yi-min
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [34] ANALYSIS OF THE FAILURE OF A VACUUM CIRCUIT-BREAKER APPLIED ON A CONSUMER - UTILITY INTERFACE
    DEATON, RJ
    SELLERS, RL
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1986, 22 (04) : 610 - 616
  • [35] Reliability Assessment of Monitoring Device for Mechanical Failure of High Voltage Circuit Breaker Based on FTA
    Cai, Yanan
    Wang, Youyuan
    Chen, Weigen
    Gao, Jun
    2014 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2014,
  • [36] Closing switch spring reliability analysis and improvement of high voltage circuit breaker operating mechanisms
    Shu, Fu-Hua
    Gaoya Dianqi/High Voltage Apparatus, 2007, 43 (05): : 368 - 370
  • [37] Dynamic Behavior Analysis of Control Valve of Hydraulic Spring Operator in High Voltage Circuit Breaker
    Su, Donghai
    Chen, Guang
    Wang, Jie
    Liu, Feng
    Liang, Quan
    MANUFACTURING AND APPLIED RESEARCH, 2014, 909 : 166 - 169
  • [38] Modelling and analysis of a high-speed circuit breaker mechanism with a spring-actuated cam
    Ahn, KY
    Kim, SH
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2001, 215 (06) : 663 - 672
  • [39] Experimental investigations on the post-arc current of the vacuum circuit breaker in an active mechanical DC circuit breaker
    Jia, Shenli
    Tang, Qiang
    Shi, Zongqian
    Mo, Yongpeng
    AIP ADVANCES, 2021, 11 (05)
  • [40] Circuit Breaker Failure Protection Strategy for HVDC Grids
    Perez-Molina, Maria Jose
    Larruskain, Dunixe Marene
    Eguia, Pablo
    Abarrategi, Oihane
    ENERGIES, 2021, 14 (14)