Effect of helical perforated twisted tape parameters on thermal and hydrodynamic performance in heat exchanger circular tube

被引:0
|
作者
Rajesh Maithani
Anil Kumar
机构
[1] DIT University,Department of Mechanical Engineering
[2] Shoolini University,School of Mechanical and Civil Engineering
来源
Heat and Mass Transfer | 2020年 / 56卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Effect of helical perforated twisted tape parameters like diameter ratio (dR/DI), relative pitch ratio (PPT/LT), perforation index (PA/TA) and Reynolds number(Re) on the thermal and hydrodynamic performance of heat exchanger circular tube experimentally analysed. Experimental data pertinent to air flow and heat transfer is generated and thermal hydrodynamic performance is determined for different sets of helical perforated twisted tape insert and flow parameters. The highest value of thermal hydrodynamic is observed at dR/DI of 0.65, PPT/LT of 0.086 and PA/TAof 10%. The maximum value of the thermal hydrodynamic performance was found to be 2.12 for the range of parameters examined.
引用
收藏
页码:507 / 519
页数:12
相关论文
共 50 条
  • [1] Effect of helical perforated twisted tape parameters on thermal and hydrodynamic performance in heat exchanger circular tube
    Maithani, Rajesh
    Kumar, Anil
    HEAT AND MASS TRANSFER, 2020, 56 (02) : 507 - 519
  • [2] Influence of perforated triple twisted tape on thermal performance characteristics of a tube heat exchanger
    Bhuiya, Muhammad Mostafa Kamal
    Roshid, Md Mamunur
    Talukder, Md Mehdi Masud
    Rasul, Mohammad Golam
    Das, Prasanjit
    APPLIED THERMAL ENGINEERING, 2020, 167
  • [3] Influence of twisted tape length on the thermal performance of a heat exchanger tube
    Panda, Jyoti Prakash
    Kumar, Bipin
    Kumar, Manoj
    Patil, Anil Kumar
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2023, 83 (06) : 650 - 663
  • [4] Numerical analysis of performance of tube heat exchanger with center-perforated tapered twisted tape
    Yadav, Ajeet
    Gupta, Rajesh
    Mohit, Manish Kumar
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2025, 47 (01) : 16 - 30
  • [5] PERFORMANCE ENHANCEMENT BY PERFORATED TWISTED TAPE TUBE INSERT WITH SINGLE AND DOUBLE V CUTS IN A HEAT EXCHANGER TUBE
    Kumar, Bipin
    Patil, Anil Kumar
    Kumar, Manoj
    Jain, Siddharth
    HEAT TRANSFER RESEARCH, 2020, 51 (05) : 395 - 406
  • [6] HYDRODYNAMIC AND THERMAL PERFORMANCE OF TWISTED TAPE INSERT PROVIDED IN HEAT EXCHANGER TUBES: A REVIEW
    Datt, Ravi
    Kumar, Anil
    Bhist, Mangal Singh
    Kothiyal, Alok Darshan
    Maithani, Rajesh
    FRONTIERS IN HEAT AND MASS TRANSFER, 2019, 12
  • [7] Effect of Twin Delta-Winged Twisted-Tape on Thermal Performance of Heat Exchanger Tube
    Eiamsa-Ard, Smith
    Nuntadusit, Chayut
    Promvonge, Pongjet
    HEAT TRANSFER ENGINEERING, 2013, 34 (15) : 1278 - 1288
  • [8] Experimental Investigation on Thermo-Hydraulic Performance of Heat Exchanger Tube with Solid and Perforated Circular Disk Along with Twisted Tape Insert
    Kumar, Alok
    Singh, Satyendra
    Chamoli, Sunil
    Kumar, Manoj
    HEAT TRANSFER ENGINEERING, 2019, 40 (08) : 616 - 626
  • [9] Heat transfer and thermal performance characteristics of heat exchanger tube fitted with perforated twisted-tapes
    Thianpong, Chinaruk
    Eiamsa-ard, Petpices
    Eiamsa-ard, Smith
    HEAT AND MASS TRANSFER, 2012, 48 (06) : 881 - 892
  • [10] Heat transfer and thermal performance characteristics of heat exchanger tube fitted with perforated twisted-tapes
    Chinaruk Thianpong
    Petpices Eiamsa-ard
    Smith Eiamsa-ard
    Heat and Mass Transfer, 2012, 48 : 881 - 892