Rapid and sensitive detection of Pseudomonas aeruginosa in bottled water by loop-mediated isothermal amplification

被引:0
作者
Shuhong Zhang
Xiaoke Xu
Qingping Wu
Jumei Zhang
机构
[1] State Key Laboratory of Applied Microbiology (Ministry—Guangdong Province Jointly Breeding Base),
[2] Guangdong Provincial Public Laboratory for Applied and New Technology of Microbiology,undefined
[3] Guangdong Provincial Key Laboratory of Microbial Culture Collection and Application,undefined
[4] Guangdong Institute of Microbiology,undefined
来源
European Food Research and Technology | 2013年 / 236卷
关键词
Loop-mediated isothermal amplification; Detection; Bottled water;
D O I
暂无
中图分类号
学科分类号
摘要
A loop-mediated isothermal amplification (LAMP) assay for the rapid detection of Pseudomonas aeruginosa in bottled water was developed and evaluated. Four primers, including two outer primers and two inner primers, were specially designed by targeting the ecfX gene. The LAMP assay showed high specificity, with no false-positive or false-negative results among the 108 bacterial strains tested, including 81 strains of P. aeruginosa. The detection limit in pure culture was 15.7 CFU/mL, which is approximately 100-fold more sensitive than that of ecfX-PCR. In artificially contaminated water samples spiked with low level (3.1 CFU/250 mL) of P. aeruginosa, the LAMP assay could detect the target organisms accurately after 10 h of enrichment, in contrast to 12 h of enrichment for ecfX-PCR. In the case of bottled water samples, 9.17 % (10/109) of the samples were found to be positive by LAMP, which was in accordance with the results from GB 8538-2008 method. The LAMP assay established in this study is a simple, sensitive, and rapid protocol for the detection of P. aeruginosa. It provides an important diagnostic tool for the drinking water produce industry and regulatory agencies to better control potential risks associated with consumption of bottled water.
引用
收藏
页码:209 / 215
页数:6
相关论文
共 128 条
[1]  
Silby MW(2011)Pseudomonas genomes: diverse and adaptable FEMS Microbiol Rev 35 652-680
[2]  
Winstanley C(2006)Bacteriological quality of drinking water from dispensers (coolers) and possible control measures J Food Prot 69 3043-3046
[3]  
Godfrey SA(2008)Comparison of the bacteriological quality of tap water and bottled mineral water In J Hyg Environ Health 211 504-509
[4]  
Levy SB(2011)Bacteriological quality of bottled natural mineral waters commercialized in Hungar Food Control 22 591-595
[5]  
Jackson RW(2006)Microbiological evaluation of bottled non-carbonated (‘‘still’’) water fromdomestic brands in Greece Int J Food Microbiol 107 68-72
[6]  
Baumgartner A(2011)Monitoring the bacteriological quality of Italian bottled spring water from dispensers Food Control 22 333-336
[7]  
Grand M(2004)PCR-based assay for differentiation of J Clin Microbiol 42 2074-2079
[8]  
Zamberlan da Silva ME(2011) from other pseudomonas species recovered from cystic fibrosis patients J Appl Microbi 111 893-903
[9]  
Santana RG(2007)Rapid and sensitive detection of J Microbiol Methods 70 20-29
[10]  
Guilhermetti M(2009) in chlorinated water and aerosols targeting gyrB gene using real-time PCR Diagn Microbiol Infect Dis 63 127-131