摘要
This paper presents experimental findings of carbon fibre reinforced polymer (CFRP) strengthened cold-formed steel built-up channels subjected to axial load. In order to sensitively detect the buckling strengths and failure modes, twenty-four built-up columns were tested in which twelve columns were unadorned and another twelve columns were strengthened using CFRP sheets. The columns were tested for ultimate load, lateral displacement and failure modes. Tension coupon tests were conducted to determine the material properties of test specimens. The experimental results were compared with the design load calculated according to AISI S100-16 specification and are found to be in good agreement. It is established that the use of CFRP for strengthening increases the ultimate load and delays the buckling.
引用
收藏
页码:415 / 424
页数:9
相关论文
共 75 条
[1]  
Bambach MR(2009)Axial capacity and design of thin-walled steel SHS strengthened with CFRP Thin-Walled Structures 47 1112-1121
[2]  
Jama HH(2009)Adhesively bonded joints in composite materials: An overview Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications 223 1-18
[3]  
Elchalakani M(2017)Experimental investigation of CFRP strengthened I-shaped cold formed steel beams JurnalTeknologi 78 1-7
[4]  
Banea MD(2006)Strengthening of tensile steel members and bolted joints using adhesively bonded CFRP plates Construction and Building Materials 20 22-33
[5]  
da Silva LF(2015)Experimental investigation of built-up cold-formed steel section battened columns Thin-Walled Structures 92 137-145
[6]  
Chakravarthy N(2010)Environmental durability of a CFRP system for strengthening steel structures Construction and Building Materials 24 1682-1689
[7]  
Naganathan S(2008)Strength assessment of adhesive-bonded joints Computational Materials Science 43 157-164
[8]  
Kalavagunta S(2014)CFRP strengthening and rehabilitation of degraded steel welded RHS beams under combined bending and bearing Thin-Walled Structures 77 86-108
[9]  
Mustapha KNB(2007)Strengthening of circular hollow steel tubular sections using high modulus CFRP sheets Construction and Building Materials 21 839-845
[10]  
Colombi P(2009)CFRP strengthening of rectangular steel tubes subjected to end bearing loads: Effect of adhesive properties and finite element modelling Thin-Walled Structures 47 1020-1028