Multiple location constraints based industrial robot kinematic parameter calibration and accuracy assessment

被引:2
作者
Shanshan He
Lei Ma
Changya Yan
Chen-Han Lee
Pengcheng Hu
机构
[1] Wuhan Institute of Technology,Manufacturing Intelligence Engineering Research Center
[2] Huazhong University of Science and Technology,School of Mechanical Science and Engineering
来源
The International Journal of Advanced Manufacturing Technology | 2019年 / 102卷
关键词
Industrial robot; Accuracy; Kinematic calibration; Multiple location constraints;
D O I
暂无
中图分类号
学科分类号
摘要
Kinematic calibration of industrial robots is an effective method of improving robot accuracy, and thus robot performance, especially when working with offline programming. The state-of-art industrial applications are lacking an easy-to-operate, reliable, and economic solution, hence forbidding frequent on-site calibration. This study presents a robot kinematic calibration method to improve the accuracy of six-axis industrial robots, using multiple location constraints. The robot parameters are calibrated by controlling a robot to reach the same location in different poses. Two standard devices and a non-contact equipment, non-bar device, are used for measurement. The proposed calibration process applies three identification methods and two compensation methods that can be mixed and matched, allowing flexible combinations of solutions to fit various industrial conditions. The proposed measurement/calibration system is economic, easy-to-operate, reliable, and suitable for express user-site industrial robot kinematic calibration, avoiding extensive production interruption. Actual experiments are carried out to verify the effects of joint zero calibration. These experiments demonstrate the proposed method’s ability to improve the accuracy of robots, and thus improve the robot work quality using offline programming.
引用
收藏
页码:1037 / 1050
页数:13
相关论文
共 35 条
[1]  
Zhenhua W(2014)A distance error based industrial robot kinematic calibration method Ind Robot: An Int J 41 439-446
[2]  
Hui X(1986)Industrial robot forward calibration method and results J Dyn Syst Meas Control 108 1-8
[3]  
Guodong C(2013)Absolute calibration of an ABB IRB 1600 robot using a laser tracker Robot Comput Integr Manuf 29 236-245
[4]  
Whitney D(2014)Absolute robot calibration with a single telescoping ballbar Precis Eng 38 472-480
[5]  
Lozinski C(2013)Kinematic calibration of a five-bar planar parallel robot using all working modes Robot Comput Integr Manuf 29 15-25
[6]  
Rourke JM(2015)Kinematic calibration of a six-axis serial robot using distance and sphere constraints Int J Adv Manuf Technol 77 515-523
[7]  
Nubiola A(2008)Kinematic parameter calibration method for industrial robot manipulator using the relative position J Mech Sci Technol 22 1084-606
[8]  
Bonev IA(1991)Autonomous calibration of single-loop closed kinematic chains formed by manipulators with passive endpoint constraints IEEE Trans Robot Autom 7 597-221
[9]  
Nubiola A(1955)A kinematic notation for lower-pair mechanisms based on matrices ASME J Appl Mech 22 215-463
[10]  
Bonev IA(2014)Calibration of an industrial robot using a stereo vision system Procedia Eng 69 459-400