Shaking Table Test and Analysis of Reinforced Concrete Frame with Steel Shear Wall with Circular Opening and Slit Damper

被引:0
|
作者
Hye-Min Shin
Hee-Du Lee
Kyung-Jae Shin
机构
[1] Kyungpook National University,Department of Architectural, Civil, Environmental, and Energy Engineering
关键词
Shaking table test; X-braced steel rod; Steel shear wall; Slit damper;
D O I
暂无
中图分类号
学科分类号
摘要
Earthquakes of 5.8 and 5.4 Richter scale recently occurred one after another in Korea, changing the Korean peninsula from an earthquake safe zone but ‘earthquake danger zone’. Therefore, seismic reinforcements must expand to include structures with low seismic resistance in order to prepare for earthquakes on a larger scale in the future. This study investigated the performances of various seismic reinforcement systems such as X-braced steel rod reinforcement, steel shear wall with circular opening reinforcement, and slit damper reinforcement using shaking table test and computational analyses of seismic data in order to establish a proper seismic reinforcement plan. These three seismic reinforcement systems could increase the stiffness and strength of existing structures and reduce maximum drift ratio in the event of an earthquake.
引用
收藏
页码:1420 / 1430
页数:10
相关论文
共 50 条
  • [31] Shaking table tests of steel frame-steel plate shear wall and composite column-steel beam frame structures
    Yang P.
    Feng L.
    He H.
    Li F.
    Liu L.
    Niu C.
    Wei H.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2023, 42 (04): : 10 - 18
  • [32] Application of FBG Sensors in Shaking Table Test of Frame-Shear Wall Structure Model
    Sun, Li
    Zhang, Haixia
    Liang, Dezhi
    Li, Zhe
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 2653 - 2656
  • [33] Shaking table test on the collapse process of a three-story reinforced concrete frame structure
    Li, Shuang
    Zuo, Zhanxuan
    Zhai, Changhai
    Xu, Shiyu
    Xie, Lili
    ENGINEERING STRUCTURES, 2016, 118 : 156 - 166
  • [34] Analytical model for steel frame-reinforced concrete infill slit wall system
    Department of Civil Engineering, Zhejiang University, Hangzhou 310027, China
    Jianzhu Jiegou Xuebao, 2006, 5 (39-46):
  • [35] Analysis On Seismic Property Of Steel Frame-steel Plate Shear Wall with Slit
    Xu Songzhi
    Liu Jiacheng
    Peng Tao
    2013 FOURTH INTERNATIONAL CONFERENCE ON DIGITAL MANUFACTURING AND AUTOMATION (ICDMA), 2013, : 238 - +
  • [36] Shaking table test on a precast concrete shear wall structure with discontinuous vertical distributing reinforcements
    Cai Q.
    Song X.
    Xiao X.
    Gu X.
    Zhang S.
    Liao X.
    Su Q.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (07): : 91 - 99
  • [37] Shaking table model test and FE analysis of a reinforced concrete mega- frame structure with tuned mass dampers
    Jiang, Qing
    Lu, Xinzheng
    Guan, Hong
    Ye, Xianguo
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2014, 23 (18): : 1426 - 1442
  • [38] Shaking table testing of a reinforced concrete frame retrofitted with a steel oval member equipped with rubber cylinders
    Sung, Yu-Chi
    Hung, Hsiao-Hui
    Chou, Kuang-Wu
    Su, Chin-Kuo
    Hsu, Chia-Wei
    Hsu, Chia-Chuan
    ENGINEERING STRUCTURES, 2021, 237
  • [39] Shaking table test of prefabricated cover plane frame supporting shear wall structure in Chisha, Guangzhou
    Wen H.
    Nong X.
    Zhou Y.
    Wu Y.
    Xiao P.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 : 43 - 52
  • [40] Seismic Analysis of Reinforced Concrete Frame Using Shake Table Test
    Arastu, M.
    Moin, K.
    JOURNAL OF APPLIED ENGINEERING SCIENCES, 2023, 13 (01) : 23 - 26