Simultaneous determination of catechol and hydroquinone based on poly(sulfosalicylic acid)/functionalized graphene modified electrode

被引:0
作者
Cong Li
Weilu Liu
Yue Gu
Shuming Hao
Xiaoyi Yan
Zhiquan Zhang
Ming Yang
机构
[1] Jilin University,College of Chemistry
[2] Shenyang Pharmaceutical University,School of Pharmacy
[3] Jilin University,Department of Breast Surgery, First Hospital
来源
Journal of Applied Electrochemistry | 2014年 / 44卷
关键词
Self-assembly; Poly(sulfosalicylic acid); Poly(diallyldimethylammonium chloride)-graphene; Electrocatalysis; Catechol; Hydroquinone;
D O I
暂无
中图分类号
学科分类号
摘要
A glassy carbon electrode (GCE) modified with poly(sulfosalicylic acid) (PSA) and poly(diallyldimethylammonium chloride)-graphene (PDDA-GN) was prepared by a simple self-assembly method. The formation of films was ascribed to the electrostatic force between negatively charged PSA and positively charged PDDA-GN as well as the π–π stacking interaction between PSA and PDDA-GN. The as prepared films were characterized by scanning electron microscopy (SEM), Raman spectroscopy and electrochemical methods. Under the optimized condition, the modified GCE showed two well-defined redox waves for catechol (CT) and hydroquinone (HQ) in cyclic voltammetry (CV) with a peak potential separation of 111 mV, which ensured the anti-interference ability of the electrochemical sensor and made simultaneous determination of dihydroxybenzene isomers possible in real samples. The corresponding oxidation currents increased remarkably compared with those obtained at the bare GCE, PSA/GCE and PDDA-GN/GCE, respectively. Differential pulse voltammetry (DPV) was used for the simultaneous determination of CT and HQ. The anodic peak current of CT was linear in the concentration from 1 × 10−6 to 4 × 10−4 M in the presence of 3 × 10−5 M HQ, and the detection limit was 2.2 × 10−7 M (S/N = 3). At the same time, the anodic peak current of HQ was linear in the concentration from 2 × 10−6 to 4 × 10−4 M in the presence of 2 × 10−5 M CT, and the detection limit was 3.9 × 10−7 M (S/N = 3). The proposed method was applied to simultaneous determination of CT and HQ in tap water with satisfactory results. These results indicated that PSA/PDDA-GN is a promising modified material with great potential in electrocatalysis and electrochemical sensing.
引用
收藏
页码:1059 / 1067
页数:8
相关论文
共 200 条
[1]  
Wang J(2003)Room-temperature heterogeneous hydroxylation of phenol with hydrogen peroxide over Fe Chem Commun 5 628-629
[2]  
Park JN(2006), Co J Chromatogr A 1109 317-321
[3]  
Wei XY(1999) ion-exchanged Naβ zeolite J Chromatogr A 855 171-179
[4]  
Lee CW(2000)Simultaneous determination of positional isomers of benzenediols by capillary zone electrophoresis with square wave amperometric detection Anal Chim Acta 418 145-151
[5]  
Xie T(2000)Determination of polyphenols by high-performance liquid chromatography with inhibited chemiluminescence detection Talanta 53 661-666
[6]  
Liu Q(2001)Open tubular capillary electrochromatography in fused-silica capillaries chemically bonded with macrocyclic dioxopolyamine J Pharm Biomed Anal 25 417-424
[7]  
Shi Y(2012)Determination of some catechol derivatives by a flow injection electrochemiluminescent inhibition method Sens Actuators B 163 179-185
[8]  
Liu Q(2012)A new sensitive and selective spectrophotometric method for the determination of catechol derivatives and its pharmaceutical preparations Sens Actuators B 162 194-200
[9]  
Cui H(2009)Simultaneous determination of catechol and hydroquinone using electrospun carbon nanofibers modified electrode Electrochim Acta 54 984-988
[10]  
He C(2011)Carbon nanoparticle–chitosan composite electrode with anion, cation, and neutral binding sites: dihydroxybenzene selectivity Electrochim Acta 56 2748-2753