Preventable effects of bare-metal stent on restenosis after everolimus-eluting stent deployment

被引:0
作者
Akihiro Shirakabe
Masamichi Takano
Masanori Yamamoto
Osamu Kurihara
Nobuaki Kobayashi
Masato Matsushita
Masafumi Tsurumi
Hirotake Okazaki
Noritake Hata
Wataru Shimizu
机构
[1] Chiba-Hokusoh Hospital,Division of Intensive Care Unit
[2] Nippon Medical School,Cardiovascular Center
[3] Chiba-Hokusoh Hospital,Division of Cardiology
[4] Nippon Medical School,undefined
[5] Nippon Medical School,undefined
来源
Heart and Vessels | 2016年 / 31卷
关键词
Stent recoil; In-stent restenosis; Target lesion revascularization; Stainless steel stent; Radial force;
D O I
暂无
中图分类号
学科分类号
摘要
This case report describes a patient who underwent implantation of a bare-metal stent (BMS) for the treatment of everolimus-eluting stent (EES) restenosis caused by chronic stent recoil, and the BMS successfully escaped from duplicate restenosis and target lesion revascularization (TLR).
引用
收藏
页码:434 / 437
页数:3
相关论文
共 150 条
  • [1] Yamawaki M(2002)Randomized study with the Sirolimus-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesions. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization N Engl J Med 346 1773-1780
  • [2] Onuma Y(2014)Simultaneous occlusion of left anterior descending and left circumflex arteries by very late stent thrombosis: vascular response to drug-eluting stents assessed by intravascular ultrasound Heart Vessels 1 58-65
  • [3] Nakano M(2005)A randomized comparison of a durable polymer everolimus-eluting stent with a bare metal coronary stent: The SPIRIT first trial EuroIntervention 107 833-840
  • [4] Muramatsu T(2011)Long-term (three-year) safety and efficacy of everolimus-eluting stents compared to paclitaxel-eluting stents (from the SPIRIT III Trial) Am J Cardiol 109 2500-2502
  • [5] Nakatani S(2004)Post-sirolimus-eluting stent restenosis treated with repeat percutaneous intervention: late angiographic and clinical outcomes Circulation 123 2954-2963
  • [6] Ishibashi Y(2011)Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation Circulation 70 515-523
  • [7] Ishimori H(2007)Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: insights from the ABSORB and SPIRIT trials Catheter Cardiovasc Interv 21 26-34
  • [8] Hirano K(1993)Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents J Am Coll Cardiol 144 132-134
  • [9] Ito Y(2010)Incidence of diffuse and focal chronic stent recoil after implantation of current generation bare-metal and drug-eluting stents Int J Cardiol 102 357-358
  • [10] Tsukahara R(2005)Double-stenting of an ostial left main-stem lesion for elastic recoil Int J Cardiol 15 39-44