Load Frequency Control of Multi-Area Interconnected System Comprising DFIG-Based Wind Turbine Equipped with Coordinated Control

被引:0
作者
Preeti Sonkar
O. P. Rahi
机构
[1] National Institute of Technology,Department of Electrical Engineering
来源
Iranian Journal of Science and Technology, Transactions of Electrical Engineering | 2018年 / 42卷
关键词
Coordinated control; Droop and pitch angle control; Inertial control;
D O I
暂无
中图分类号
学科分类号
摘要
Traditionally, wind power generation has not contributed to power system frequency regulation due to decoupling between generator speed and grid frequency by power electronics devices. It has an adverse effect on load frequency control problem with increasing wind power level. The major focus of this article is to demonstrate load frequency controller for multi-area interconnected system comprising DFIG-based wind power plants equipped with coordinated frequency control technique. Single control technique such as inertial control, pitch angle control, or rotor speed control is not sufficient for all zones of wind speed. Therefore, coordination between theses controllers is required for frequency regulation of grid. In the present paper, two-area and three-area interconnected power systems comprising non-reheat thermal unit and wind power plant with coordinated control technique have been implemented. Two-area interconnected power system has been analyzed for different step load perturbations in each area. The novelty of this work is apparent from the fact that coordinated control of wind turbine for load frequency control problem of two-area and three-area interconnected power systems has not been reported in literature so far. Load frequency control incorporating coordinated control of wind turbine has been compared with inertial controller, combination of inertial and droop controller, and combination of inertial, droop and pitch angle control techniques in the case of the two-area interconnected power system, whereas it has been compared with combination of inertial, droop, and pitch angle control for the three-area interconnected power system. It has been established from the simulation results of the proposed controller that frequency and tie line power deviations have shown remarkable improvements for all wind speed zones.
引用
收藏
页码:1 / 20
页数:19
相关论文
共 79 条
  • [11] Chang-Chien LR(2008)Evaluation of the suitability of a fixed speed wind turbine for large scale wind farms considering the new UK grid code Renew Energy 33 112-55
  • [12] Yin YC(2015)Study on dynamic participation of wind turbines in automatic generation control of power systems Electr Power Compon Syst 43 44-867
  • [13] Chang-Chien LR(2013)Comprehensive review on the grid integration of doubly fed induction generator Int J Electr Power 49 818-287
  • [14] Lin WT(2009)Dynamic contribution of DFIG-based wind plants to system frequency disturbances IEEE Trans Power Syst 24 859-1913
  • [15] Yin YC(2009)Kinetic energy of windturbine generators for system frequency support IEEE Trans Power Syst 24 279-716
  • [16] Dahiya P(2005)Frequency control and wind turbine technologies IEEE Trans Power Syst 20 1905-316
  • [17] Sharma V(2006)Frequency deviation of thermal power plants due to wind farms IEEE Trans Energy Convers 21 708-199
  • [18] Sharma RN(2010)Working towards frequency regulation with wind power plants: combined control approaches IET Renew Power Gener 4 308-987
  • [19] Ekanayake J(2012)Frequency control in autonomous power systems with high wind power penetration IEEE Trans Sustain Energy 3 189-1503
  • [20] Jenkins N(2006)Inertial response of variable speed wind turbines Electric Power Syst Res 76 980-9