Load Frequency Control of Multi-Area Interconnected System Comprising DFIG-Based Wind Turbine Equipped with Coordinated Control

被引:0
作者
Preeti Sonkar
O. P. Rahi
机构
[1] National Institute of Technology,Department of Electrical Engineering
来源
Iranian Journal of Science and Technology, Transactions of Electrical Engineering | 2018年 / 42卷
关键词
Coordinated control; Droop and pitch angle control; Inertial control;
D O I
暂无
中图分类号
学科分类号
摘要
Traditionally, wind power generation has not contributed to power system frequency regulation due to decoupling between generator speed and grid frequency by power electronics devices. It has an adverse effect on load frequency control problem with increasing wind power level. The major focus of this article is to demonstrate load frequency controller for multi-area interconnected system comprising DFIG-based wind power plants equipped with coordinated frequency control technique. Single control technique such as inertial control, pitch angle control, or rotor speed control is not sufficient for all zones of wind speed. Therefore, coordination between theses controllers is required for frequency regulation of grid. In the present paper, two-area and three-area interconnected power systems comprising non-reheat thermal unit and wind power plant with coordinated control technique have been implemented. Two-area interconnected power system has been analyzed for different step load perturbations in each area. The novelty of this work is apparent from the fact that coordinated control of wind turbine for load frequency control problem of two-area and three-area interconnected power systems has not been reported in literature so far. Load frequency control incorporating coordinated control of wind turbine has been compared with inertial controller, combination of inertial and droop controller, and combination of inertial, droop and pitch angle control techniques in the case of the two-area interconnected power system, whereas it has been compared with combination of inertial, droop, and pitch angle control for the three-area interconnected power system. It has been established from the simulation results of the proposed controller that frequency and tie line power deviations have shown remarkable improvements for all wind speed zones.
引用
收藏
页码:1 / 20
页数:19
相关论文
共 79 条
  • [1] Almeida RGD(2006)Optimum generation control in wind parks when carrying out system operator IEEE Trans Power Syst 21 944-950
  • [2] Castronuovo ED(2012)Fuzzy logic-based load frequency control concerning high penetration of wind turbines IEEE Syst J 1 173-180
  • [3] Lopes JAP(2013)Intelligent LFC concerning high penetration of wind power: synthesis and real-time application IEEE Trans Sustain Energy 5 655-662
  • [4] Bevrani H(2009)Strategies for operating wind power in a similar manner of conventional power plant IEEE Trans Energy Convers 24 926-934
  • [5] Daneshmand PR(2011)Enhancing frequency response control by DFIGs in the high wind penetrated power IEEE Trans Power Syst 24 710-718
  • [6] Bevrani H(2015)Optimal generation control of interconnected power system including DFIG-based wind turbine IETE J Res 61 1-15
  • [7] Daneshmand PR(2004)Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency IEEE Trans Energy Convers 19 800-802
  • [8] Babahajyani P(2014)Market designs for the primary frequency response ancillary service—part I: motivation and design IEEE Trans Power Syst 29 421-431
  • [9] Mitani Y(2014)Market designs for the primary frequency response ancillary service—Part II: case studies IEEE Trans Power Syst 29 432-440
  • [10] Hiyama T(2008)Comparative study on the performance of control systems for doubly fed induction (DFIG) wind turbines operating with power regulation Energy 33 1438-1452