Electrochemical determination of hydroquinone using hydrophobic ionic liquid-type carbon paste electrodes

被引:0
作者
Yiyi She
Yougen Tang
Hongtao Liu
Ping He
机构
[1] Central South University,College of Chemistry & Chemical Engineering
[2] Southwest University of Science and Technology,School of Materials Science & Engineering
来源
Chemistry Central Journal | / 4卷
关键词
Glassy Carbon Electrode; Phosphate Buffer Solution; Carbon Paste Electrode; Potassium Hexacyanoferrate; Diffusion Control Mechanism;
D O I
暂无
中图分类号
学科分类号
摘要
Three types of carbon paste electrodes (CPEs) with different liquid binders were fabricated, and their electrochemical behavior was characterized via a potassium hexacyanoferrate(II) probe. 1-Octyl-3-methylimidazolium hexafluorophosphate ionic liquid (IL) as a hydrophobic conductive pasting binder showed better electrochemical performance compared with the commonly employed binder. The IL-contained CPEs demonstrated excellent electroactivity for oxidation of hydroquinone. A diffusion control mechanism was confirmed and the diffusion coefficient (D) of 5.05 × 10-4 cm2 s-1 was obtained. The hydrophobic IL-CPE is promising for the determination of hydroquinone in terms of high sensitivity, easy operation, and good durability.
引用
收藏
相关论文
共 139 条
  • [1] Zhao GH(2006)Electrocatalytic redox of hydroquinone by two forms Of L-proline J Mole Cataly A: Chem 255 86-91
  • [2] Li MF(2008)Treatment of catechol bearing wastewater in an upflow anaerobic sludge blanket (UASB) reactor: sludge characteristics Bioresource Technol 99 8917-8925
  • [3] Hu ZH(2000)Biosensor based on paraffin/graphite modified with sweet potato tissue for the determination of hydroquinone in cosmetic cream in organic phase Talanta 52 681-689
  • [4] Li HX(2005)Determination of hydroquinone in cosmetic emulsion using microdialysis sampling coupled with high-performance liquid chromatography J Pharm Biomed Anal 38 414-419
  • [5] Cao TC(2003)Determination of major phenolic compounds in water by reversed-phase liquid chromatography after pre-column derivatization with benzoyl chloride J Chromatogr A 988 145-149
  • [6] Subramanyam R(2000)Coulometric detector based on porous carbon felt working electrode for flow injection analysis Talanta 53 651-660
  • [7] Mishra IM(1999)The UV spectrophotometrica determination of migrated hydroquinone Polimery 44 690-696
  • [8] Vieira IC(2006)Determination of phenol, resorcinol and hydroquinone in air samples by synchronous fluorescence using partial least-squares (PLS) Talanta 69 1265-1268
  • [9] Fatibello-Filho O(2000)Synthesis and analytical applications of 4-aminopyrazolone derivatives as chromogenic agents for the spectrophotometric determination of phenols Anal Chim Acta 403 315-323
  • [10] Lin CH(1995)Simultaneous determination of hydroquinone ethers in cosmetics after preconcentration at a carbon paste electrode Analyst 120 2241-2244