A Randomized Trial Comparing the Efficacy of Methylene Blue Dye Alone Versus Combination of Methylene Blue Dye and Radioactive Sulfur Colloid in Sentinel Lymph Node Biopsy for Early Stage Breast Cancer Patients

被引:0
作者
Vikas Gupta
KVVN Raju
T. Subramanyeshwar Rao
C.K. Naidu
Vipin Goel
Nisha Hariharan
Ramachandra Nagarajuch
B Madhunarayana
机构
[1] Basavatarakam Indo American Cancer Hospital & Research Institute,Department of Surgical Oncology
来源
Indian Journal of Surgical Oncology | 2020年 / 11卷
关键词
Sentinel; Breast cancer; Blue dye; Radioactive colloid;
D O I
暂无
中图分类号
学科分类号
摘要
Although sentinel lymph node biopsy (SLNB) has become a standard of care for management of axilla in breast cancer patients, the technique of SLNB is still not well defined. Unlike radioactive sulfur colloid which requires nuclear medicine facilities, methylene blue dye is readily available. The purpose of this study is to validate the use of methylene blue dye alone for SLNB in early breast cancer patients. 60 patients of early breast cancer were randomized to receive either methylene blue alone (Group A-30 patients) or a combination of both methylene blue and radioactive colloid (Group B-30 patients) for detection of sentinel lymph nodes. Sentinel lymph node biopsy was done followed by complete axillary dissection in all patients. In both Groups A and B, sentinel node was identified in all 30 patients, giving identification rate of 100%. In group A, sentinel node was the only positive node in 1 patient, with a false-positive rate of 14.2%. The negative predictive value was 91.3%. The sensitivity of the procedure in predicting further axillary disease was 75% with a specificity of 95.45%. The overall accuracy was 90%. In group B, sentinel node was the only positive node in 2 cases, giving a false-positive rate of 28.7%. The negative predictive value was 95.65%. The sensitivity of the procedure in predicting further axillary disease was 83.33% with a specificity of 91.67%. The overall accuracy was 90%. Although the false-negative rate was slightly higher with methylene blue alone than that using combination (8.6%–4.3%), it was statistically insignificant. Similarly the sensitivity (75%–83.33%), specificity (95.45–91.67%), and negative predictive value (91.3%–95.67%) were also comparable between groups A and B, respectively. Negative predictive value and false-negative rates are comparable, whether blue dye is used alone or a combination of blue dye and radioactive colloid is used. Sentinel lymph node biopsy with blue dye alone is reliable and can be put to clinical practice more widely, even if nuclear medicine facilities are not available in resource constrained centers, so as to reduce long-term morbidity of axillary dissection, with similar oncological outcomes.
引用
收藏
页码:216 / 222
页数:6
相关论文
共 163 条
  • [1] Cady B(1984)Lymph node metastases. Indicators, but not governors of survival Arch Surg 119 1067-1072
  • [2] Cuschieri A(1999)Patient survival after D1 and D2 resections for gastric cancer: long-term results of the MRC randomized surgical trial Br J Cancer 79 1522-1530
  • [3] Weeden S(2004)Extended lymph node dissection for gastric cancer: who may benefit? Final results of the randomized Dutch gastric cancer group trial J Clin Oncol 22 2069-2077
  • [4] Fielding J(1984)Survival after high or low ligation of the inferior mesenteric artery during curative surgery for rectal cancer Ann Surg 200 729-733
  • [5] Hartgrink HH(1994)Surgical management of regional lymph nodes in patients with melanoma. Experience with 4682 patients Ann Surg 219 120-130
  • [6] van de Velde CJ(1994)Effects of postoperative mediastinal radiation on completely resected stage II and stage III epidermoid cancer of the lung. LCSG 773 Chest 106 297S-301
  • [7] Putter H(2007)Role of lymphadenectomy in surgical treatment of solid tumors: an update on the clinical data Ann Surg Oncol 14 2443-2462
  • [8] Bonenkamp JJ(2001)National practice patterns of sentinel lymph node dissection for breast carcinoma J Am Coll Surg 192 453-458
  • [9] Klein Kranenbarg E(2004)Blue dye versus combined blue dye radioactive tracer technique in detection of sentinel lymph node in breast cancer Eur J Surg Oncol 30 913-917
  • [10] Songun I(2010)Axillary ultrasound and fine-needle aspiration in the preoperative evaluation of the breast cancer patient: an algorithm based on tumor size and lymph node appearance AJR Am J Roentgenol 195 1261-1267